230 TimeProvider 5000 User’s Guide
098-00028-000 Revision F – May, 2012
Chapter 3
TimeProvider 5000 CLI Command Set
reboot
This command restarts one or more of the modules. Using this command can cause
a loss of outputs.
Command Syntax:
reboot {system|imc|ioc1|ioc2|exp[0-9]}
Remarks:
Selecting
system
restarts all system modules and expansion shelves.
Selecting
system
, or the only IOC, or an expansion shelf disrupts the system
outputs.
Example 1:
tp5000> reboot imc
Response 1:
The system is going down NOW!
Sending SIGTERM to all processes
Sending SIGKILL to all processes
Requesting system reboot
Restarting system.
U-Boot 1.1.6 (Oct 23 2008 - 13:17:59) MPC83XX
Symmetricom Time Provider 5000 (TP5000) IMC
Clock configuration:
Coherent System Bus: 166 MHz
Core: 333 MHz
Local Bus Controller: 166 MHz
Local Bus: 41 MHz
DDR: 333 MHz
SEC: 55 MHz
I2C1: 166 MHz
I2C2: 166 MHz
TSEC1: 166 MHz
TSEC2: 166 MHz
USB MPH: 0 MHz
USB DR: 55 MHz
CPU: MPC8313E, Rev: 10 at 333.333 MHz
INFO: Initializing IOMEM for regset 0
DRAM: 256 MB
NAND: 256 MiB
Using default environment
........................................
Symmetricom tp5000_imc
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...