098-00028-000 Revision F – May, 2012
TimeProvider 5000 User’s Guide 247
Chapter 3
TimeProvider 5000 CLI Command Set
Remarks :
See
below for IOC Clock Status descriptions.
Level :
User, Config, and Admin
Table 3-4. IOC Clock Status
IOC Clock
Status
Description
Possible Next
State
Conditions Required
for Next Transition
State
Warmup
This IOC is warming up.
Freerun
Ref mode = frequency
Warm-up complete
Fast-track
Ref mode = time
GPS qualified
Warm-up complete
Freerun
This IOC is operating
without a reference
Freerun
Ref mode changed from
frequency to time
Fast-track
Input becomes qualified
Fast-track
This IOC has a qualified
input and clock is
stabilizing.
Bridging
This IOC no longer has a
qualified input.
Normal-track
Clock stabilized
Normal
This IOC has a qualified
input and meets all
specifications.
Fast-track
Clock not stabilized
adequately
Bridging
This IOC no longer has a
qualified input.
Bridging
This IOC no longer has a
qualified reference, but
remains operating within
specification associated
with normal_track
operation.
Holdover
Bridging time exceeded
Fast-track
Input reference
re-qualified in less than
bridging time.
Holdover
This IOC no longer has a
qualified reference
Fast-track
Input becomes qualified
See Note below.
Fail
Hardware failure detected
on this IOC
none
N/A
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...