294 TimeProvider 5000 User’s Guide
098-00028-000 Revision F – May, 2012
Chapter 4 Provisioning
Provisioning PTP
Table 4-7. Hybrid (Multicast-Hybrid) Proprietary Profile
Attribute
Default for TP 5000
Range for TP 5000
clockClass
Not defined
6, 7, 13, 14, 52, 58, 248
Announce Interval
-3
-4 to +4
Sync Interval
-7
-7 to +7
Domain
4
0 to 255
Table 4-8. Option 1 - SSM Mapping to QL and clockClass per G.781 and G.8265-1
Option 1 SSM (hex)
Clock QL
PTP clockClass
PQL
04FF
QL-PRC
84
1
08FF
STU
82
2
0CFF
QL-SSU-A
90
3
0CFF
Type I
90
4
78FF
QL-SSU-B
96
6
10FF
QL-SEC/EEC1
104
7
30FF
QL-DNU
110
9
Others (or absent)
Invalid
n/a
15
Table 4-9. Option 2 - SSM Mapping to QL and clockClass per G.781 and G.8265-1
Option 2 SSM (hex)
Clock QL
PTP clockClass
PQL
04FF
QL-PRS
80
1
08FF
QL-STU
82
2
0CFF
QL-ST2
86
3
0CFF
Type I
86
4
78FF
QL-TNC
90
5
7CFF
QL-ST3E
100
6
10FF
QL-ST3E/EEC2
102
7
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...