Chapter 4 Provisioning
Provisioning the Input Reference
Setting an E1/T1 Input as Reference
An E1 or T1 input can be configured as a frequency reference. For details about
configuring the E1 or T1 input parameters, see
Example
To provision I/O ports 1 and 2 as inputs and use either as the reference, perform the
following steps:
1. Login at the Admin or Config-user level (see
2. Type
set ref mode frequency
and press
Enter
.
3. Type
set ref criteria priority
and press
Enter
.
4. Type
set io port1 input
and press
Enter
.
5. Type
set io port2 input
and press
Enter
.
6. Type
set input state port1 enable
and press
Enter
.
7. Type
set input state port2 enable
and press
Enter
.
8. Type
show ref
and press
Enter
to verify that the reference mode has been set
to Frequency..
Note:
Command “
set ref mode time”
has the same meaning as
“
set tod-source GPS”
and the command “
set ref mode
frequency”
has the same meaning as “
set tod-source sys”
.
The
command has been deprecated.
Note:
The reference criteria MANUAL is no longer supported. Only
PRIORITY and SSM are supported for reference selection.
Manual selection of a reference input can be done by disabling all
reference input ports except the desired one.
The “set ref override” command is no longer supported.
Note:
Disabling the input port will clear all alarms and events related
to this port.
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...