098-00028-000 Revision F – May, 2012
TimeProvider 5000 User’s Guide 381
Chapter 6 Maintenance and Troubleshooting
Troubleshooting
System Health
Aggregation of
system alarms
indicator
SYS
Off - IMC, IOC operating normally
n/a
Amber - IMC, IOC operational
Minor Alarm(s)
Use “show alarm” command to
view alarm IDs and descriptions.
for corrective
actions.
Red - IMC, IOC operational Major
or Critical Alarm(s)
Use “show alarm” command to
view alarm IDs and descriptions.
for corrective
actions. After taking corrective
actions, use “reboot” command to
reboot the card that had the major
or critical alarm..
IMC Alarm
IMC module
alarm/fault
indicator
ALM
Off - IMC operating normally
n/a
Flashing Green - Software
starting up
Wait for IMC to finish booting.
Amber - IMC operational Minor
Alarm(s)
Use “show alarm” command to
view alarm IDs and descriptions.
for corrective
actions.
Red - IMC operational
Major/Critical Alarm(s)
Use “show alarm” command to
view alarm IDs and descriptions.
for corrective
actions. After taking corrective
actions, use “reboot imc”
command.
Table 6-4. LED Conditions for the IMC (Continued)
Indicator
Label
Description
Corrective Action
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...