406 TimeProvider 5000 User’s Guide
098-00028-000 Revision F – May, 2012
Appendix A System Messages
Message provisioning
Message provisioning
The TimeProvider 5000 and its expansion shelves support logging of events using
syslog defined facility and severity codes and system defined facility codes as
follows:
Facility codes
4 Security/authorization messages
20 Time Provider 5000 Messages (events and alarms)
21 TimeProvider 5000 Command History
22 TimeProvider 500 Messages (events and alarms)
Severity codes
2 (critical) Critical: critical conditions
3 (major) Error: error conditions
4 (minor) Warning: warning conditions
5 (event) Notice: normal but significant condition
The syslog message format is as follows:
Mmm dd hh:mm:ss
host_name Process-name AlarmID,Index,Severity, MsgText
Where:
Mmm = Month; dd = date; hh:mm:ss = system time
Notes:
1.
Severity codes 2, 3, and 4, are also indicated by the Alarm
LED(s) on the IMC and IOC modules.
2.
Severity Code 2 indicate Critical Alarms.
3.
Severity Code 3 indicates Major Alarms.
4.
Severity Code 4 indicates Minor Alarms.
5.
Severity Code 5 indicates Events and does not affect the Alarm
LED.
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...