098-00028-000 Revision F – May, 2012
TimeProvider 5000 User’s Guide 417
Appendix A System Messages
System Notification Messages
Input poor SSM
(See
for
Secondary Index Info)
IOC
61
Minor
No
<input> poor SSM
<input> poor SSM
cleared
Check system input
reference quality
level
None required
Input SSM changed
(See
for
Secondary Index Info)
IOC
62
Event
Yes
<input> SSM
changed
None required
Time input not
tracking
IOC
63
Minor
No
Time input not
tracking
Time input not
tracking cleared
Check GNSS
antenna location,
cable connections
None required
Internal reference
data loss
IOC
64
Minor
No
Internal reference
data loss
Internal reference
data loss cleared
This alarm could
occur during
configuration. If the
alarm still present 1
minute after
configuration,
reboot system. If
alarm still present,
replace IOC module
None required
OBSOLETE
n/a
65
n/a
n/a
n/a
n/a
IO module not
present
IMC
66
Event
Nos
IO module not
present
IO module present
Check IO module
slot
None required
Redundancy data
transfer error
(See
for
Secondary Index Info)
IOC
67
Major
No
Redundancy data
transfer error (code)
Redundancy data
transfer error (code)
cleared
Reboot IOC that is
showing alarm. If
alarm is still
present, contact
Symmetricom
Technical Support
Table A-1. System Notification Messages (Continued)
Description
Comp
ID
Event
ID
MsgLevel
Trans-
itory
MsgText
Corrective Action
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...