098-00028-000 Revision F – May, 2012
TimeProvider 5000 User’s Guide 445
Appendix B Specifications and Factory Defaults
Specifications
11
U1
1PPS Status
0x00 = normal
0x01 = Time sync equipment
(atomic clock)
in holdover mode)
0x02 = do not use
0x03 = Time sync equipment
(high-stability crystal clock)
in holdover mode)
0x04 = Transport carrier equipment in
holdover mode)
Other values are reserved
12
U1
TAcc
PPS jitter category (0
255):
0 =
0 ns
1 =
15 ns
2 =
3
0 ns
3 =
45 ns
.
.
.
.
255 =not defined
Note:
This value is fixed to 255 for
transmission and base station
equipment
13
U1
Reserved
Reserved
14
U1
Reserved
Reserved
15
U1
Reserved
Reserved
Table B-15. TP E30 - Time Information Message Payload Contents for 1PPS+TOD Outputs (Continued)
Byte
Offset
Data
Type
Name
Units
Notes