326 TimeProvider 5000 User’s Guide
098-00028-000 Revision F – May, 2012
Chapter 4 Provisioning
Provisioning the Programmable E1/T1 Outputs
If the output frame type supports SSM and SSM is enabled for the output port, then
the output signal will contain the system SSM value.
SSM value based on the clock state of the TP5000.
2048kHz Frame Type
To provision Port 1 as an output port with a frametype of 2048kHz, CRC disabled,
SSM disabled, and to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set io port1 output
and press
Enter
.
3. Type
set output frametype port1 freq2048khz
and press
Enter
.
4. Type
set output crc port1 disable
and press
Enter
.
5. Type
set output ssm port1 disable
and press
Enter
.
6. Type
set output state port1 enable
and press
Enter
.
CCS Frame Type
To provision Port 2 as an output port with a frametype of CCS, CRC enabled, SSM
enabled, SSM-bit of 4, and to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set io port2 output
and press
Enter
.
3. Type
set output frametype port2 ccs
and press
Enter
.
Table 4-18. Output SSM-value vs. Clock State
Clock State
Output SSM-value
Warm-up
PQL=9 - Do not use for Sync
(DUS)
Free-run
PQL of oscillator
Fast-lock
PQL of oscillator
Normal
PQL of reference
Bridging
Last PQL of reference
Holdover
PQL of oscillator
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...