098-00028-000 Revision F – May, 2012
TimeProvider 5000 User’s Guide 345
Chapter 4 Provisioning
Setting the System Date and Time
Figure 4-33. Set SyncE Command Hierarchy
QL State for SyncE Outputs
1. Login at the Admin or Config-user level.
2. Type
set synce ql-state exp0 all enable
and press
Enter
QL Mode for SyncE Outputs
1. Login at the Admin or Config-user level.
2. Type
set synce output-ql-mode exp0 port 1 bidirectional
and press
Enter
ESMC for SyncE Outputs
1. Login at the Admin or Config-user level.
2. Type
set synce esmc exp0 port 1 enable
and press
Enter
Setting the System Date and Time
The TimeProvider 5000 Time of Day can be set either by an external source, or
manually with the “set clock” command. You can set the time and date only in the
frequency reference mode (or SYS tod-source mode), but if the reference mode has
been set to time (default) or if TOD source has been set to GPS (default)], it is not
possible to set the time manually.
Note:
The
set tod-source
command has been deprecated ,
but can still be used as an alternate approach.