Provisioning the Probe
Set Grandmaster PTP IP Address
To specify the Grandmaster to be used with the Probe the following parameters be
provisioned. See
for procedures to set the Grandmaster PTP IP address:
Grandmaster Clock ID
Grandmaster IP Address
Grandmaster VLAN Address (if any).
Table F-8. Set Grandmaster PTP IP Address Procedures
TimeMonitor PDV
CLI Command
1. Click on the
Command
radio button to put
TimeMonitor PDV into the proper mode for
making Probe changes.
2. Click the Login button to login to the Probe,
which will prompt for Username and Password.
3. Select desired Probe port using radio buttons.
4. Enter the IP address, Netmask and Gateway
for the 1588 Master server for selected port.
5. If Master is part of a VLAN, click VLAN check
box. Enter VLAN ID in the box that appears.
6. Enter the Clock ID for the Master server.
NOTE
: For a TP 5000 Grandmaster, use the
show
ptp-status
command to find clock ID .
7. Repeat steps 3 through 6 for the other port.
Use the command:
set ptp-probe IOC1-x active-probe
gm-clock-id <clock-id> gm-ip
<addr> [vlan-id <vlan>]
where x is the port number on the IOC
Example:
For following Grandmaster specs:
Clock ID = 00:B0:AE:FF:FE:00:00:06
IP address = 192.168.1.11
VLAN ID = 35:
1. Login at the Admin or Config-user level.
2. Type
set ptp-probe ioc1-1
active-probe gm-clock-id
00:B0:AE:FF:FE:00:00:06 gm-ip
192.168.1.11 vlan-id 35
and
press
Enter
.
3. If there is no VLAN for the
Grandmaster, type
set ptp-probe
ioc1-1 active-probe
gm-clock-id
00:B0:AE:FF:FE:00:00:06 gm-ip
192.168.1.11
and press
Enter
.
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...