4
158
TimeSource 3100
TL1 Reference
097-72020-01 Issue 9: November 2003
Retrieve Equipment (cont’d)
Response Format:
<sid> <date> <time>
M <ctag> COMPLD
"<aid>::::<spec_block>"...
/*LINK:<link>,CMD:<command>*/
;
The parameters which may be displayed in the <spec_block> are listed below.
Aid
Parameter
Value
Parameter Description
ALL
MONITOR=a
a = ALW
Monitor is used for alarm purposes
a = INH
Monitor is not used for alarm purposes
TS3100
BYPASS=a
(990-72020-04
Systems only)
a = ALW or
INH
During holdover, the traffic-bearing E1 spans on
the ESCIU module pass through the
TimeSource 3100 without being re-timed (ALW)
or the E1 spans continue to be re-timed (INH)
FREQ=a
a=5
Frequency for both remote oscillator inputs is 5
MHz
a=10
Frequency for both remote oscillator inputs is
10 MHz
TOD=a
a=CISCO
Serial message sent is Cisco format
a=NTP4
Serial message sent is NTP Type 4 format
a=NONE
No serial message is sent
ALMCOND=a
a=ALW
Alarm conditioning for outputs is enabled
a=INH
Alarm conditioning for outputs is disabled
Summary of Contents for TimeSource 3100
Page 1: ...TimeSource 3100 GPS Primary Reference Source 097 72020 01 Issue 9 November 2003 ...
Page 49: ...3 Chapter Installation This chapter provides the steps required for installation and power up ...
Page 109: ...Chapter 4 TL1 Reference This chapter provides information for using the TL1 language ...
Page 203: ...Chapter 6 Specifications This chapter provides equipment specifications ...