F73 – Alarm Control / Status
F73<SP>THRESHOLD<SEP><nanoseconds><CR>
The XL-GPS will set the new time error threshold and returns the following string if the
command is successful.
OK<CR><LF>
Set or query Timeout Delay using the TIMEOUT command. To query the current setting,
enter:
F73<SP>TIMEOUT<CR><LF>
The XL-GPS responds:
F73<SP>TIMEOUT<SEP><seconds><SP>s<CR><LF>
where <seconds> is the timeout in seconds, between 0 and 86400.
To set Timeout Delay, enter a command string in the following format:
F73<SP>TIMEOUT<SEP><seconds><CR><LF>
The XL-GPS will set the new timeout delay and responds:
OK<CR><LF>
Led blinking can be ENABLED or DISABLED using the BLINK command. To enable LED
blinking, enter:
F73<SP>BLINK<SEP>ENABLE<CR>
The XL-GPS responds:
OK<CR><LF>
To disable LED blinking, enter:
F73<SP>BLINK<SEP>DISABLE<CR>
The XL-GPS responds:
OK<CR><LF>
Use the SUPPRESS command to suppress all F73 faults from triggering alarms for a
specified duration after the XL-GPS power is turned on. To check the SUPPRESS status,
enter:
F73<SP>SUPPRESS<CR>
The XL-GPS responds in the following format:
098-00116-000 Rev. A
...............................
Page 103 of 221
Summary of Contents for XL-GPS
Page 1: ...XL GPS Time Frequency Receiver User Guide CD Part Number 098 00116 000 Rev A 5 May 2010 ...
Page 14: ......
Page 34: ......
Page 50: ......
Page 196: ......
Page 214: ...IRIG IRIG Standard Format A 098 00116 000 Rev A Page 200 of 221 ...
Page 215: ......
Page 216: ...F World Map of Time Zones 098 00116 000 Rev A Page 202 of 221 ...
Page 219: ......
Page 220: ...I Certificate of Volatility See the following document 098 00116 000 Rev A Page 206 of 221 ...
Page 224: ......
Page 225: ...J Declaration of Conformity See the following document 098 00116 000 Rev A Page 208 of 221 ...