F73<SP>POWER-ON<SEP>MINOR<SEP>ALARM<SEP>SUPPRESS<SEP> <seconds><CR><LF>
where:
F
= ASCII character F.
73
= function number.
<seconds>
= seconds from 0 to 86400.
<SP>
= ASCII space character.
<SEP>
= one or more space characters, either comma, space, or tab.
<CR>
= Carriage Return.
<LF>
= Line Feed.
To set the SUPPRESS enter a command using the following format:
F73<SP>SUPPRESS<SEP><seconds><CR>
The seconds can be set to any value from 0 to 86400. The XL-GPS responds:
OK<CR><LF>