5: Function Reference
jumper can be identified because it is the only three-prong jumper on the Main CPU card,
and is labelled “J3”.
Units are shipped to the customer with no jumper installed. The jumper is used by
Symmetricom technicians to test and configure the unit. With this jumper installed, the
operation and integrity of the XL-GPS are compromised.
Warning: Do not run the XL-GPS with the jumper, unless specifically directed to
do so by a qualified Symmetricom technician.
To test the state of the factory mode jumper:
F100<S>J<CR>
where:
F
= ASCII character F
100
= unit function number
<S>
= space
J
= specify User Name command
<CR>
= input line terminator
XL-GPS responds:
F100 J FACTORY MODE = 1<CR><LF>
or
F100 J FACTORY MODE = 0<CR><LF>
F100 K I L L – Reboot
Use function F100 K I L L to reboot the unit. Use F100 K I L L after upgrading the system
firmware.
K I L L is a case-sensitive command. When entering this command,
use all capital letters
and
put spaces between each letter
.
To reboot the unit, enter:
F100 K<S>I<S>L<S>L<CR>
For example:
F100 K I L L<CR>
XL-GPS responds:
Page 122 of 221
.................................
098-00116-000 Rev. A
Summary of Contents for XL-GPS
Page 1: ...XL GPS Time Frequency Receiver User Guide CD Part Number 098 00116 000 Rev A 5 May 2010 ...
Page 14: ......
Page 34: ......
Page 50: ......
Page 196: ......
Page 214: ...IRIG IRIG Standard Format A 098 00116 000 Rev A Page 200 of 221 ...
Page 215: ......
Page 216: ...F World Map of Time Zones 098 00116 000 Rev A Page 202 of 221 ...
Page 219: ......
Page 220: ...I Certificate of Volatility See the following document 098 00116 000 Rev A Page 206 of 221 ...
Page 224: ......
Page 225: ...J Declaration of Conformity See the following document 098 00116 000 Rev A Page 208 of 221 ...