5: Function Reference
Clock Reading
Pulse
001:00:00:00.000000
Start
001:00:00:00.000001
No Change
001:00:00:01.000000
Stop
001:01:00:00.000000
No Change
001:00:00:00.000000
Start (etc...)
For example, to produce a repetitive 5 microsecond pulse occurring every 10 microseconds
(i.e., repetitive pulses with 100 kPPS frequency with the start time or rising-edge on-time and
the stop time or falling-edge at 5
m
S
- or 10
m
S
pulse period with 5
m
S
pulse width), enter:
F111 PPO XXX:XX:XX:XX.XXXXX0 XXX:XX:XX:XX.XXXXX5<CR>
XL-GPS responds:
OK<CR><LF>
Or, for example, to produce a repetitive 50-microsecond pulse occurring every 100
microseconds (i.e., repetitive pulses with 10 kPPS frequency with the start time or rising-
edge at 5
m
S
and the stop time or falling-edge at 55
m
S
- or 100
m
S
pulse period with 50
m
S
pulse width), enter:
F111 PPO XXX:XX:XX:XX.XXXX05 XXX:XX:XX:XX.XXXX55<CR>
XL-GPS responds:
OK<CR><LF>
Or, for example, to produce a repetitive 50-microsecond pulse occurring every 100
milliseconds (i.e., repetitive pulses with 10 PPS frequency with the start time or rising-edge
at 5
m
S
and the stop time or falling-edge at 55
m
S
- or 100ms pulse period with 50
m
S
pulse
width), enter:
F111 PPO XXX:XX:XX:XX.X00005 XXX:XX:XX:XX.X00055<CR>
XL-GPS responds:
OK<CR><LF>
Or, for example, to produce a repetitive one-minute pulse occurring every hour, enter:
F111 PPO XXX:XX:10:00.000000 XXX:XX:11:00.000000<CR>
Page 136 of 221
.................................
098-00116-000 Rev. A
Summary of Contents for XL-GPS
Page 1: ...XL GPS Time Frequency Receiver User Guide CD Part Number 098 00116 000 Rev A 5 May 2010 ...
Page 14: ......
Page 34: ......
Page 50: ......
Page 196: ......
Page 214: ...IRIG IRIG Standard Format A 098 00116 000 Rev A Page 200 of 221 ...
Page 215: ......
Page 216: ...F World Map of Time Zones 098 00116 000 Rev A Page 202 of 221 ...
Page 219: ......
Page 220: ...I Certificate of Volatility See the following document 098 00116 000 Rev A Page 206 of 221 ...
Page 224: ......
Page 225: ...J Declaration of Conformity See the following document 098 00116 000 Rev A Page 208 of 221 ...