6: Option Cards
10 MHz Output:
Sine Amplitude
13dBm +/- 1.5dBm into 50
W
Sine Harmonic Distortion
< -30 dBc
Square Wave
TTL into 50
W
Synchronization
Phase locked to the XL-GPS's internal 10 MHz oscillator to within
10ns
Connector
Female BNC
CPU-Aware
No
1 MPPS Output:
Sine Amplitude
> 4.5 V into 50
W
Sine Harmonic Distortion
< 0.5 V into 50
W
Square Wave
49 to 51%
Synchronization
Phase locked to the clock 10MHz to within 10ns
Connector
Female BNC
CPU-Aware
No
5 MPPS Output:
Output High:
> 4.5 V into 50
W
Output Low:
< 0.5 V into 50
W
Duty cycle:
45 to 55%
Synchronization
Phase locked to the clock 10MHz to within 10ns
Connector
Female BNC
CPU-Aware
No