2: System Specifications
1 PPS Out
A time-stable 1 PPS (one pulse per second) output is provided. If no reference is available,
the 1 PPS pulse will be as stable as the internal oscillator.
Pulse width:
20
m
S +/-1
m
S
On time edge:
Rising
Accuracy:
Refer to
“Time and Frequency Accuracy” on page 4
Amplitude:
TTL Levels into 50
W
Qty:
1
Connector:
BNC female
Code Out
The default output is IRIG-B-120 AM. Configuration is via the Keypad, Serial I/O, and
Network port.
Format:
IRIG B-120, B000, B120 1344, B000 1344
IRIG-A130, A000
NASA 36
Amplitude (AM):
3 Vp-p, into 50
W
+/-10%
Ratio (AM):
3:1 +/-10%
Amplitude (DC):
TTL into 50
W
Qty:
1
Connector:
BNC female
Phasing:
In phase with carrier ± 10
m
S
Accuracy:
Refer to
“Time and Frequency Accuracy” on page 4
Five flags are encoded in the control function segment of the IRIG B code, (IRIG B-120,
B000, B120 1344, B000 1344). The first flag encoded at element P5+40ms is the LOCK
indicator. It is a binary 1 when the reference source has become unlocked. The second flag
encoded at element P5+60ms is a binary 1 when the worst case time error exceeds
threshold 1 element P5+70ms is a binary 1 when the worst case time error exceeds
threshold 2. Element P5+80ms encodes a binary 1 when the error exceeds threshold 3 and
P5+90ms when the error exceeds threshold 4.
The time code resets as follows:
Page 8 of 221
.................................
098-00116-000 Rev. A
Summary of Contents for XL-GPS
Page 1: ...XL GPS Time Frequency Receiver User Guide CD Part Number 098 00116 000 Rev A 5 May 2010 ...
Page 14: ......
Page 34: ......
Page 50: ......
Page 196: ......
Page 214: ...IRIG IRIG Standard Format A 098 00116 000 Rev A Page 200 of 221 ...
Page 215: ......
Page 216: ...F World Map of Time Zones 098 00116 000 Rev A Page 202 of 221 ...
Page 219: ......
Page 220: ...I Certificate of Volatility See the following document 098 00116 000 Rev A Page 206 of 221 ...
Page 224: ......
Page 225: ...J Declaration of Conformity See the following document 098 00116 000 Rev A Page 208 of 221 ...