F8 – Continuous Time Once-per-Second
DDD
= day-of-year
HH
= hours
MM
= minutes
SS
= seconds
:
= colon separator.
Q
= time quality character (see the following table)
The time quality character, “Q”, is one of the following characters:
SPACE
= Time error is less than time quality flag 1’s threshold
.
= Time error has exceeded time quality flag 1’s threshold
*
= Time error has exceeded time quality flag 2’s threshold
#
= Time error has exceeded time quality flag 3’s threshold
?
=
Time error has exceeded time quality flag 4’s threshold
Or
A reference source is unavailable
The four time quality thresholds are set by
F5 – Time-Quality Setup
.
See
“F13 – Time Error” on page 67
for more information.
Command Line
For example, to initiate Continuous Time once-per-second, enter
F8<CR>
The XL-GPS replies:
199:11:19:30<CR><LF>
199:11:19:31<CR><LF>
199:11:19:32<CR><LF>
To stop Continuous Time Once-Per-Second, press Ctrl-C on your keyboard to stop it.