F42 - Multicode Output Configuration
The Serial/Network port will respond with the Time Reference for the Multicode output
card. The following example requests the Time Reference for the Multicode output card:
F42 T<CR><LF>
The Serial/Network port will respond with the following string:
F42 UTC<CR><LF>
The Time Reference for the Multicode output card may be set as follows:
F42 <SP>T<SP><TREF><CR
where
F42 = string representing the Function Number
T = ASCII letter indicating that time reference will be set.
<SP> = one space.
<TREF> = Time Reference, UTC, LOCAL, STANDARD, or GPS
and the serial port will respond with the following ASCII string:
OK<CR><LF>
The Serial/Network port will respond with the message “ERROR 01 VALUE OUT OF
RANGE” if the input string was in the correct format but contained a value, probably
numeric, that was out of the range of acceptable values.
The Serial/Network port will respond with the message “ERROR 02 SYNTAX” if it
receives a string in an incorrect format.
The Serial/Network port will respond with the message “ERROR 03 BAD/MISSING
FIELD” if the input string lacks a required field.
098-00116-000 Rev. A
...............................
Page 71 of 221
Summary of Contents for XL-GPS
Page 1: ...XL GPS Time Frequency Receiver User Guide CD Part Number 098 00116 000 Rev A 5 May 2010 ...
Page 14: ......
Page 34: ......
Page 50: ......
Page 196: ......
Page 214: ...IRIG IRIG Standard Format A 098 00116 000 Rev A Page 200 of 221 ...
Page 215: ......
Page 216: ...F World Map of Time Zones 098 00116 000 Rev A Page 202 of 221 ...
Page 219: ......
Page 220: ...I Certificate of Volatility See the following document 098 00116 000 Rev A Page 206 of 221 ...
Page 224: ......
Page 225: ...J Declaration of Conformity See the following document 098 00116 000 Rev A Page 208 of 221 ...