background image

!

E07

M1 Hall Error

Handset shows E07

All Columns Stop Working, Press any key shows RST 

System need reset

E08

M2 Hall Error

Handset shows E08

All Columns Stop Working Press any key shows RST 

System need reset

E09

M3 Hall Error

Handset shows E09

All Columns Stop Working Press any key shows RST 

System need reset

E10

M4 Hall Error

Handset shows E10

All Columns Stop Working, Press any key shows RST 

System need reset

E11

M5 Hall Error

Handset shows E11

All Columns Stop Working, Press any key shows RST 

System need reset

E12

M6 Hall Error

Handset shows E12

All Columns Stop Working, Press any key shows RST 

System need reset

E13

communication interrupt
between controller A and B

Handset shows E13

All Columns Stop Working, Press any key shows RST 

System need reset

H01

over heat protection/Duty
cycle protection

Handset shows H01

All Columns Stop Working, Press any key useless,  

Handset shows current height after rest

Remark:

1

 6 lift columns synchro working by 2 control boxes, the main control box is "A", and the other one is "B" 

2

M1M2M3 controlled by Single control box or "A" control box, M4M5M6 controlled by control box "B"

3

 Overcurrent protection trigger condition

:(

1

over loaded when columns lifting up 

2

colums still running 

when reach highest/lowest position 

3

mechanical fault ,electric fault 

4

 Hall Error trigger condition

:(

1

+5V/GND/H1/H2/ wire fault 

2

motor core fault , no signal or few signal 

output 

5

Communication interrupt between A and B  trigger condition:

1

controller B or controller A_SCI2 fault

2

connection between controller A and B fault

6

Over heat trigger condition Too high temperature for Heating elements 

7

Duty cycle trigger condition continuously working more than 4 minutes, need rest 16 minutes

Reviews: