Rinnai Australia
8
Operation & Installation Manual
ABOUT YOUR CONTROLLER
TO TURN YOUR HEATER ON
The 'Push Button Control Panel' is located at the top left edge of the heater.
Step 1. Press ‘ON’/‘OFF’ button
once.
The electronic ignition sparker will
be able to be heard.
Step 2. The electronic ignition stops when
the pilot flame has been
established, the main burner then
ignites off the pilot and is
automatically preset to Stage 7 -
High Flame. The blue LED Power
Indicator,
will be constantly
illuminated indicating heater is in
operation.
Step 3. Flame height may be adjusted after
1 minute of operation. To change
the burner and fan settings press
to increase flame height and
to decrease flame height.
FLAME HEIGHT & FAN SPEED SETTINGS
TO TURN YOUR HEATER OFF
To turn the heater 'OFF' press the 'ON'/'OFF' Button
once. The blue LED Power Indicator
, will extinguish to
indicate that the appliance has returned to the in OFF condition.
INTERRUPTION TO ELECTRICITY OR GAS SUPPLY DURING OPERATION
Interruption to the power or gas supply will turn your heater off. Restart will be required This is a safety feature
designed to ensure that un-attended starts do not occur.
RESTART PROCEDURE AFTER INTERRUPTION TO ELECTRICITY SUPPLY
To restart your heater once power has been restored follow the steps for “TO TURN YOUR HEATER ON” above.
RESTART PROCEDURE AFTER INTERRUPTION TO GAS SUPPLY
The instant gas supply is interrupted the heater will attempt re-ignition for a period of 60 seconds.
If the heater has not re-lit after 60 seconds the gas control will go to 'Gas Lock-out'. The convection fan will remain
on for 4 minutes to cool the appliance.
To restart your heater once gas has been restored:
Step 1. Ensure gas supply has been re-established to heater.
Step 2. To re-set the gas control turn 'OFF' the heater by pressing 'ON/OFF' button
once.
Step 3. In rapid succession Press button
, 3 times. (Turn 'ON', then 'OFF', then 'ON' again), within a 5 second
period.
BEFORE PROCEEDING ENSURE THE GAS AND ELECTRICITY ARE TURNED ON.
When the heater is in the OFF condition (the power supply connected and switched ON but the
heater turned OFF) the Power Indicator will be extinguished, this is normal.
The relationship between the flame
height and fan speed are preset and
can not be independently adjusted.
FLAME HEIGHT
1
2
3
4
5
6
7
FAN SPEED
HIGH LOW LOW LOW HIGH HIGH HIGH
When the heater is in the OFF/STANDBY condition (power supply connected and switched ON) the
blue LED Power Indicator will be extinguished. This is normal.
NOTE
a
b
c
d
a
b
Control for square fronted fascia
Control for bevel fronted fascia
a
b
c
d
NOTE
NOTE
a
b
a
a