Rinnai Australia
16
Operation & Installation Manual
REMOTE / THERMOSTATIC CONTROLLED OPERATION
Flame Height And Fan Speed
The flame height and fan speed are not individually adjustable. Flame height and fan speeds are selected by the
microprocessor according to the difference between the set temperature and the ambient temperature of the room.
The fan speed automatically adjusts to the corresponding flame height. The fan speed is not able to be selected
by the operator. When the heater is operated in ‘Manual Temperature Mode’ the flame height is automatically
selected by the microprocessor to achieve and maintain the ‘set’ temperature. As an example, if the room is much
colder than the ‘set’ temperature, the flame height and corresponding fan speed will be high. As the room heats up
and gets close to the ‘set’ temperature the flame height and corresponding fan speed will revert to lower settings.
When the heater is operated in ‘Flame Mode’ the flame height is set by the operator.
Flashing Small Flame Symbol ‘ON’
The small flashing flame symbol
on the RF controller display indicates the room
temperature is within 0.5°C of set temperature.
Program Modes
The appliance can be programmed to operate during four separate periods in one day, resulting in a possible 28
operating periods per week. A weekday program can be set so the program is used Monday to Friday. Similarly, a
weekend program can be set for Saturday to Sunday. The entire week can also have the same program.
PROGRAMMING OF PROGRAM MODES
Step 1.
With the controller ‘OFF’, press and hold the
‘P’
button
for approximately 2 seconds. The LCD will
display
‘PROG’. ‘Pd’
and the current time and the day
‘MO’
will flash.
Step 2.
To select the day range press the
‘UP
’ button
or
‘DOWN’
button
until the desired day range has
been chosen. The day ranges are as follows:
MO
TU
WE
TH
FR
MO TU WE TH FR
SA
SU
SU - SA
SU MO TU WE TH FR SA
Step 3.
Press the
‘OK’
button
to enter the selected day range. The LCD will display
‘PROG’. ‘P1’
and the
‘TIME’
+
‘HOUR’
+
‘AM’
will flash.
Factory default settings
If you do nothing to change the programming the following default settings would be
available if you set it to automatic mode.
Time Period
Start Time
Temperature °C
Suggested Time Period Settings
Period 1
6:00 am
20°C
- Morning
Period 2
8:30 am
15°C
- Day time
Period 3
5:00 pm
21°C
- Evening
Period 4
10.30 pm
15°C
- Night time
To revert back to the default settings once you have reset the periods, in rapid
succession press the following sequence of buttons
‘P’ - ‘T’ - ‘T’ - ‘DOWN’.
Holding the ‘UP’ or
‘DOWN’
buttons for more than 2 seconds will scroll through the day ranges.
17
17
STEP 2
A/M
PWR
T
P
DOWN
UP
OK
A/M
PWR
OK
T
P
10
A/M
PWR
T
P
DOWN
UP
OK
A/M
PWR
OK
T
DOWN
UP
STEP 1
16
STEP 3
A/M
PWR
T
P
DOWN
UP
OK
A/M
PWR
T
P
DOWN
UP
11
15
16
10
15
NOTE
11