Rinnai Australia
21
Operation & Installation Manual
HOW TO OPERATE YOUR HEATER
MANUAL SWITCH MODE
If you lose your remote controller or the
batteries go flat you can still operate your
unit in
*
‘Manual Switch Mode’.
Step 1. Press ‘ON’/‘OFF’ button
until the sparker can be heard.
The button is discretely located
on the ‘Manual Control Switch
Panel’ at the bottom right of the
heater.
Step 2. Once the electronic sparker has activated the pilot flame will ignite, the main burner will ignite off the pilot &
automatically go to Stage 7-High Flame. The LED Power Indicator
, will be constantly illuminated
indicating heater operation in ‘Manual Switch Mode’. For bevelled fascia the heater will remain on Stage 7-
High Flame setting, flame adjustment will not be possible.
For square profile fascia the flame may be adjusted from Stage 7-High Flame to low flame setting by
pressing the flame up/down buttons,
, on the manual control pad.
Step 3. To turn the heater ‘OFF’ press the ‘ON’/’OFF’ Button
. The LED Power Indicator
will flash indicating
that the appliance has functioned in ‘Manual Switch Mode’ and is independent of the remote controller.
If the controller is lost or if the batteries go flat the unit will operate as described above, however,
extreme caution must be used because the appliance will continue to operate on ‘HIGH’ setting
only.
For Square Fascia only
• Temperature adjustment is possible by pressing buttons
up or down until desired
temperature is achieved.
For Bevelled Fascia only
• NO lower adjustment of temperature is possible without re-engaging the thermostatic controller.
LOSS OF REMOTE CONTROL FUNCTION
*
NOTE: Once the 'Manual Switch Mode' has been selected the heater will only operate by pressing the ‘Manual
Switch’, once you have pressed the ‘Manual Switch’ the heater will not respond to the remote controller.
TO REGAIN REMOTE CONTROL
Step 1. Turn the heater 'ON' with the 'Manual Switch', follow steps 1 and 2 of “MANUAL SWITCH MODE” above.
Step 2. On your remote control hand set, select refer to “MANUAL TEMPERATURE MODE” on page 18 for
'Manual Mode'.
Step 3. Press the 'UP' or 'DOWN' button to raise or lower the temperature, this will send a signal to your heater
reinstating remote control.
Step 4. Remote Control has now been reinstated and normal programming can be selected.
GAS SUPPLY DISRUPTION
Should disruption to gas supply occur the appliance will go into 'lockout' after sparking for 1 minute. Under
'lockout' the LED Power Indicator
will remain illuminated. To start the appliance again, press and release the
'ON / OFF'
button twice after gas supply resumes.
POWER DISRUPTION
In the event of power failure / disruption the heater will turn 'OFF' and will need to be manually turned 'ON' again
when power is restored. This is a safety feature. Refer to, “* NOTE: Once the 'Manual Switch Mode' has been
selected the heater will only operate by pressing the ‘Manual Switch’, once you have pressed the ‘Manual
Switch’ the heater will not respond to the remote controller.” on page 18.
11
Square Fascia
11
12
4
9
Bevelled Fascia
11
10
4
9
9
12
11
9
NOTE
12
9
11