HEATER LOCATION
ENCLOSURE REQUIREMENTS
Consult a qualified electrician if direct wiring is required as it must comply with the
requirements of AS/NZS 5601 & AS 3000 and any other relevant local regulations.
The electrical cord must not come into direct contact with the heated parts of the appliance
or flue system.
If the power cord is damaged and requires replacing, it must be replaced by a licensed
tradesperson. It must be a genuine replacement part available from Rinnai.
RDV3610ETR
The appliance must be positioned on a flat level surface. As this
appliance has a cool outer casing it can be installed into a
decorative fireplace constructed from materials such as wood or
plaster. The only exception is the cladding above the appliance
which must be non-combustible and extend at least 400 mm above
the appliance in accordance with the drawings on page 4, page 27
and page 39.
If the appliance is elevated from the ground, a base must be
constructed using suitable material with supporting joists, capable
of easily supporting a minimum of 175kg. (Flue must be supported
independently of the appliance).
RDV3611ETR
Cladding material need not be non-combustible. Ensure
construction is in accordance with drawings on page 4, page 27
and page 39.
ENCLOSURE DIMENSIONS
Enclosure dimensions as shown. The enclosure dimensions
specified are critical to the successful installation of this appliance
and must be strictly adhered to.
IMPORTANT
110
0~1
125
60
0 m
in
85
0
m
in
Typical Frame Layout
1
2
9
5m
m
91
5
m
m
18
30
m
m
Corner Installation Layout