INSTALLATION:
Caution: Be sure to turn off hot and cold water supplies
before installing or servicing faucet.
1.
Push valve bodies through holes in sink from underneath. Make
sure
flange nuts
and
mounting washers
are on underside of sink.
Valve with red striped hose (hot) is on the left and blue (cold) is on
the right. Put gasket (LN-129) over
valve body
. Thread escutcheon
(LN-128) onto
valve body
. The top of the valve spindle should
measure 1-7/8” from mounting surface (See rough in drawing).
2. Thread collar (LN-112 or LN-111) on to
valve body
until it reaches the
escutcheon (LN-128).
3. Standard or LWG handle installation: Place bushing (LN-115) on
valve spindle. Turn valves to off position (CR style: turn clockwise;
LWG, LCF, LPO, LAM, and standard style: turn hot clockwise,
turn cold counterclockwise). Place handle (LN-131) on bushing.
Thread screw (LN-146 or LN-121) into valve and push plug button
(T-33R and T-33B) into top of handle. CR, LCF, LPO and LAM
handle installation: Place handle on valve spindle and thread screw
(LN-121 or LN-134) into valve.
4. Tighten
flange nuts
and
mounting washers
from underneath sink and
secure with
mounting screws
if necessary.
5. Swivel spout option: Place spout assembly (LN-200) in centerbody
(LN-197). Thread nut (LN-199) onto centerbody (LN-197).
Rigid spout option: Thread screw (LN-205) into the bottom of the
spout assembly (LN-200). Place spout assembly (LN-200) in center
7/8" (22mm) min
1-3/8" (35mm) max
hole size
1-1/16" (27mm) min
1-7/16" (37mm) max
hole size
Escutcheon
S-254-CR handle
S-254
standard
handle shown
S-254-LAM
S-254-LPO
S-254-LCF
S-254-LTM
2-7/16
(61 mm)
Dimensions
Origins,
S-254, S-254-CR, S-254-LAM, S-254-LPO, S-254-LCF, S-254-LTM
Note:
Dimensions subject to
change without notice.
body (LN-197). Thread nut (LN-199) onto center body (LN-197).
6. Drop assembled center body and spout through center hole of deck.
Secure assembly to sink using nut (SPF-108) and washer (LN-138).
7. Thread tee (LN-189) onto the end of the center body (LN-197).
Thread
flex hose adapters
into tee using pipe sealant on the threads.
Attach
flex hoses
to
flex hose adapters
.
8. Connect hot supply to left tube and cold supply to right tube using
appropriate connectors.
9. It is very important to thoroughly flush the supply lines to prevent
foreign matter, i.e. copper chips, sand, stones, etc. from damaging
the sealing surfaces of cartridge. Remove aerator and open hot and
cold to full open then open both supplies. Let water run through
hot and cold long enough to flush supply lines thoroughly. Shut off
faucet and replace aerator. Check for leaks.
Cartridge Replacement (KN-113 or KN-114):
1. Remove plug button (T-33, T-33R or T-33B), loosen Philip head
screw (LN-121) and remove handle, (LN-131 or LN 152).
2. Remove collars (LN-112) by turning counter clockwise, do not use
wrench as this may damage the surface finish.
3. Place wrench on cartridge hex nut (KN-113, KN-114). Turn
wrench counter clockwise until cartridge is removed.
4. Install new cartridge. Turn cartridge with wrench until cartridge
does not turn easily then turn 1/4 to 1/2 turn further. Reassemble
handle in reverse fashion.