INSTALLATION:

Caution: Be sure to turn off hot and cold water supplies 

before installing or servicing faucet.

1. 

Push valve bodies through holes in sink from underneath. Make 

sure 

flange nuts

 and 

mounting washers

 are on underside of sink. 

Valve with red striped hose (hot) is on the left and blue (cold) is on 

the right.  Put gasket (LN-129) over 

valve body

. Thread escutcheon 

(LN-128) onto 

valve body

. The top of the valve spindle should 

measure 1-7/8” from mounting surface (See rough in drawing).

2.  Thread collar (LN-112 or LN-111) on to 

valve body

 until it reaches the 

escutcheon (LN-128). 

3.  Standard or LWG handle installation: Place bushing (LN-115) on 

valve spindle.  Turn valves to off position (CR style: turn clockwise; 

LWG, LCF, LPO, LAM, and standard style: turn hot clockwise, 

turn cold counterclockwise).  Place handle (LN-131) on bushing.  

Thread screw (LN-146 or LN-121) into valve and push plug button 

(T-33R and T-33B) into top of handle. CR, LCF, LPO and LAM 

handle installation: Place handle on valve spindle and thread screw 

(LN-121 or LN-134) into valve.

4.   Tighten 

flange nuts

 and 

mounting washers

 from underneath sink and 

secure with 

mounting screws

 if necessary.

5.  Swivel spout option: Place spout assembly (LN-200) in centerbody 

(LN-197). Thread nut (LN-199) onto centerbody (LN-197). 

Rigid spout option: Thread screw (LN-205) into the bottom of the 

spout assembly (LN-200). Place spout assembly (LN-200) in center 

7/8" (22mm) min

1-3/8" (35mm) max

hole size

1-1/16" (27mm) min

1-7/16" (37mm) max

hole size

Escutcheon

S-254-CR handle

S-254  

standard

handle shown

S-254-LAM

S-254-LPO

S-254-LCF

S-254-LTM

2-7/16

(61 mm)

Dimensions 

 

Origins,

 S-254, S-254-CR, S-254-LAM, S-254-LPO, S-254-LCF, S-254-LTM

Note:

  

Dimensions subject to

change without notice.

body (LN-197). Thread nut (LN-199) onto center body (LN-197).

6.  Drop assembled center body and spout through center hole of deck.  

Secure assembly to sink using nut (SPF-108) and washer (LN-138).

7.  Thread tee (LN-189) onto the end of the center body (LN-197). 

Thread 

flex hose adapters

 into tee using pipe sealant on the threads. 

Attach 

flex hoses

 to 

flex hose adapters

.

8.  Connect hot supply to left tube and cold supply to right tube using 

appropriate connectors.

9.  It is very important to thoroughly flush the supply lines to prevent 

foreign matter, i.e. copper chips, sand, stones, etc. from damaging 

the sealing surfaces of cartridge. Remove aerator and open hot and 

cold to full open then open both supplies. Let water run through 

hot and cold long enough to flush supply lines thoroughly. Shut off 

faucet and replace aerator. Check for leaks. 

Cartridge Replacement (KN-113 or KN-114):

1.  Remove plug button (T-33, T-33R or T-33B), loosen Philip head 

screw (LN-121) and remove handle, (LN-131 or LN 152).

2.  Remove collars (LN-112) by turning counter clockwise, do not use 

wrench as this may damage the surface finish.

3.  Place wrench on cartridge hex nut (KN-113, KN-114). Turn 

wrench counter clockwise until cartridge is removed.

4.  Install new cartridge. Turn cartridge with wrench until cartridge 

does not turn easily then turn 1/4 to 1/2 turn further. Reassemble 

handle in reverse fashion.

Lavatory Faucet  

S-254 Series

Installation and Service Instructions

Origins

®

For California Residents

WARNING:

 This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

Reviews: