User’s Manual
Synaccess Networks, Inc.
www.synaccess-net.com
(760) 930 – 0473 Page 37 of 46
Figure 27 - Serial Port Setup Menu (Web Page)
************************************************************
* *
* *
* Port 1 Configuration Menu *
* *
* *
************************************************************
>
> 1) Baud rate..................................38400
2) Data bits:(7 or 8).........................8
3) Stop bits(1 or 2)..........................1
4) Parity(1-Even,2-Odd,3-None)................3
5) Flow control(1-hardware,2-XonXoff,3-None)..3
6) Port name..................................Undefined
7) Save:
8) Quit:
>Please select a parameter to change:
Figure 28 – Serial Port N Parameter Entry Table
•
Baud Rate:
The system supports the following baud rates: 2400, 4800, 9600, 19200, 38400, 57600
and 115200.
It is strongly recommended that Master port and a user serial port have the same data rate
while exchanging data between them so that data loss is eliminated. If you must run both
ports using different baud rates, Flow Control (hardware handshaking) should be enabled
on all connected serial console ports.
Please also note that when Telnet access is used for exchanging data between the system’s
Ethernet interface port and user communication equipment, without enabling flow control,