2  Important Safety Precautions for Hardware Installation 

 

2.1 Safety Precautions 

It is important that you read this section before attempting any of the hardware installation and maintenance 
procedures in this guide. 

 

  
The following instructions are important for your safety and for the functioning of the unit. Read the instructions 
carefully before attempting the installation 
 

WARNING!

 

To reduce the risk of fire or electrical shock, never remove the cover of the unit.  No user serviceable parts 
inside.  Repair should be done by authorized service personnel only.

 

 
The unit should be installed in indoor with ambient temperature and sufficient airflow.  
 

WARNING!

  

Ensure that the hardware you are working with is disconnected from the power supply during installation. This 
means that the unit’s power cable and network cables must remain disconnected until you are instructed to make 
the connections. Follow the instructions in the procedures carefully. 
 
This equipment is disconnected from the power supply by removing the power cord(s) from the power outlet. It is 
therefore important to locate the unit close to a power outlet that is easily accessible. 
 
  

  

WARNING!

  

When connecting a hardware unit to a power supply, for your safety you must always connect it to a grounded wall 
outlet.  
   

  

2.2 Battery Replacement 

 
A 3.0V Lithium battery is installed in the unit for internal Real-Time Clock and system data retention. The battery 
should last at least 10 years.  If the battery needs to be replaced, please ask qualified personnel for the service.  Here 
is the instruction for the replacement: 
 

a)

 

Use CR2032 type,  3.0V Lithium battery. 

b)

 

Remove the old battery from the battery holder, 

c)

 

Insert the new replacement to the holder with “+” facing up.

 

 

CAUTION:  

Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the 
Instructions.

Summary of Contents for netBooter NP-02

Page 1: ...User s Manual Synaccess Networks Inc www synaccess net com 760 930 0473 Page 1 of 46 User s Manual For netBooter Series NP 02 NP 08 NP16 and NPB 20 Part 1140 May 2007 Synaccess Synaccess Networks Inc...

Page 2: ...s been tested and shown to comply with the following FCC rule Part 15 Subpart J and ICES 003 UL Safety Standards Compliance netBooter Series products have been tested and found to be accordance with t...

Page 3: ...ET ACCESS 14 3 6 WEB ACCESS 15 3 7 EMAIL ACCESS 16 3 8 SNMP INFORMATION 17 3 9 AUTOPING AND POWER REBOOT 19 4 USING CONTROL COMMAND 20 5 USING CONFIGURATION MENU 22 5 1 STARTING CONFIGURATION MENU 22...

Page 4: ...16 System Main Menu Web Page 24 Figure 17 System Access Setup Menu Terminal Screen 25 Figure 18 System Access Control Menu Web Page 26 Figure 19 Network Configuration Menu Terminal Screen 28 Figure 2...

Page 5: ...NEMA 5 15P Y Y UL FCC Class A NP 16A20 2 U 16 1 20 NEMA L5 20P Y Y UL FCC Class A NP 16A30 2 U 16 1 30 NEMA L5 30P Y Y UL FCC Class A NPB 20 0 U Vertical 20 16 Switchab le 1 15 NEMA 5 15P Y Y UL FCC...

Page 6: ...tables and graphical icons Download SNMP MIB files for convenience or view an online help manual SNMP MIB capability An SNMP Simple Network Management Protocol agent is integrated in the system for an...

Page 7: ...operation status AutoPing and reboot user equipment Connect your system to a power outlet and assign the system network IP address or URL The NP system will ping the user equipment periodically in eve...

Page 8: ...s Manual Synaccess Networks Inc www synaccess net com 760 930 0473 Page 8 of 46 1 3 Front and Back Panel Figure 3 NP 08 Front and Back Panel Illustration Figure 4 NP 02 Front and Back Panel Illustrat...

Page 9: ...status 2 NP system power On Off status LED Indication of system power On Off status 3 Ethernet Link status LED When the LED is illuminated Ethernet port and a LAN connection are established 4 Ethernet...

Page 10: ...rnet Port RJ45 10 base T 10 based T Ethernet port for connection to LAN 9 Manual Switch Outlet power output switch Momentarily pressing down the button to index to the desired outlet Pressing down for...

Page 11: ...e unit s power cable and network cables must remain disconnected until you are instructed to make the connections Follow the instructions in the procedures carefully This equipment is disconnected fro...

Page 12: ...econd method is to select Reload Factory Defaults from the Main Menu The Main Menu can be viewed by running a terminal emulation program such as Window s Hyper Terminal or Telnet Upon the system start...

Page 13: ...ttings and operate unreserved power outlets 3 3 Local Master Port Access To access and configure the system from the master port you need to connect a RS232 port from your work station to the Local Ma...

Page 14: ...nfiguration section of this document for information on how to setup the network parameters Once the network connection is established at your workstation prompt you need to enter telnet ip_addr The t...

Page 15: ...to the Telnet Access section for methods to get the system IP address You also need to make sure that web access is enabled as a default setting If the access is not enabled please refer to Section U...

Page 16: ...Figure 10 Factory default setting for user name is admin The default password is admin Figure 10 Web Access Login Entry Table 3 7 Email Access To establish this access method the system s network con...

Page 17: ...the value of a single variable or a set of variables An SNMP Set request modifies the value of a variable You need to know the name of a variable before your can fetch or modify a variable s value A...

Page 18: ...e currentAlarmThreshold 3 1 1 2 Aggregated AC current draw threshold for each power inlet or power cord currentDrawStatus1 3 1 1 3 First AC current monitoring reading For a system equipped with single...

Page 19: ...ping network equipment The pinged equipment is attached to a specific power outlet It reboots user equipment power source if a network connection is not detected any more However user equipment never...

Page 20: ...re detailed information about how to setup email accounts Once the system starts or a Telnet session is open you are ready to send control command to the system Type command help to have a complete li...

Page 21: ...s Ethernet network interface nwshow Displays network Status ping Pings a host E g ping 192 168 0 1 or ping yahoo com prsv n Reserves power outlet n for current login user pset n v Sets power outlet n...

Page 22: ...he system are connected to LAN If you have already logged on to the system enter the command setup and you will see Main Menu table as shown in Figure 15 Without login to the system if you enter comma...

Page 23: ...ection 4 Lists help information Menu selection 5 Exit menu operation 5 2 System Main Menu This is a top level system main configuration menu as shown in Figure 15 and 16 Figure 15 System Main Menu Ter...

Page 24: ...power outlets even if they are reserved by other users Helpful info control command rb n executes the same function as the option 1 Option 2 Setup System Enters System Access Setup submenu Helpful in...

Page 25: ...to factory default settings You must login at Administration level Option 8 Save settings Save current system configuration parameters Option 9 Quit Returns to previous menu 5 3 System Access Setup M...

Page 26: ...unication Equipment terminal connector Since the system s Local Master Port and Modem device ports are not complementary you need to use a NULL Modem cable with both male connectors For information ab...

Page 27: ...ction 2 5 for a list available MIB objects that the system supports Default to disable SNMP Trap Enabling Enable or disable Trap sending If this option is enabled Traps are sent if there is a power re...

Page 28: ...ot Static IP Address A static IP Address is an IP address that never changes This IP address will be used if a DHCP server IP has no IP offered or DHCP automatic IP address is disabled Network Configu...

Page 29: ...rt Number Specifies a Telnet port number Default value is 23 POP3 Email Server Specifies POP incoming Email server address The system supports POP3 Internet Email Protocols not web based Email service...

Page 30: ...assword authentication enter Y for this entry Helpful Info use command emailget to immediately check incoming emails Check Email Interval This entry specifies how often the system checks incoming emai...

Page 31: ...et session Use command Help is view available command delimiter symbols For example sending email subject mySite3 johnW 123456 rb 2 will reboot power outlet 2 on the NP system named as mySite3 The use...

Page 32: ...f the system name does not match user name does not exists or the name does not have the privilege to operate the designated serial console port or power outlet port or if there is a command syntax er...

Page 33: ...he system to level 2 verbose mode in which detailed emailing activities are displayed Use command emailget to check incoming emails immediately Use command emailsend to send a test mail immediately 5...

Page 34: ...erial console ports Please also note that when Telnet access is used for exchanging data between the system s Ethernet interface port and user communication equipment without enabling flow control you...

Page 35: ...atus is changed accordingly 3 Repeat the procedure 1 and 2 for change the next power outlet state If you run a terminal program power outlet setup starts with the following menu Figure 26 Power Outlet...

Page 36: ...w to display all power outlet status Figure 27 List of Power Outlet Status Terminal Screen Power Outlet Port Parameters and Status Port Name Status Reserved By Timer 1 Switch5 On Open Off 2 Undefined...

Page 37: ...6 Date 7 4 1988 1 Power Outlet name Undefined 2 Power Port 1 On 0 Off 1 3 Power Outlet timer 1 On 0 Off 1 4 Enable AutoPing Reboot if Network down Y N N 5 Max Network Down Time seconds Allowed 60 6 A...

Page 38: ...f time the system will start reboot processes for the power outlet Note AutoPing starts power reboot process if and only if the following two conditions are met 1 NPC system is active on the network i...

Page 39: ...y will be 300 Enter 0 for this setting if you schedule the power outlet simply change power state from on to off or from off to on a specific time and date Enter 1 for the setting if you schedule the...

Page 40: ...Feb 12th 1 00 am Timer Start Time 2 12 1 00 00 Start the event at 1 00am on Feb 12th Timer Period 6 6 seconds Timer Toggle Duration 5 5 seconds Reboot duration is 5 seconds Timer Loop Count 1 Reboot o...

Page 41: ...that lets you to view and change serial console port and power outlet operation status With this web page you are able to View on off status for each power outlet As shown in the table Power outlet 1...

Page 42: ...User s Manual Synaccess Networks Inc www synaccess net com 760 930 0473 Page 42 of 46 Figure 34 Viewing and Changing System Operation Status...

Page 43: ...eriod This constitutes Purchaser s sole and exclusive remedy in the event of a defect This limited warranty covers defects encountered in the normal use of the Product during the warranty period and d...

Page 44: ...s warranty or in any manner arising out of or connected with the sale or anticipated use of the product In no event shall Synaccess be liable for any damages whatsoever in excess of the purchase price...

Page 45: ...cation of serial port activated 7 CTS Clear To Send When hardware flow control is enabled if this signal is raised an external device can send data to Local Master Port 8 RTS Request To Send When hard...

Page 46: ...B9 Female RJ45 8 pin Pin No Signal 1 DCD 2 TxD 3 RxD 4 DSR 5 GND 6 DTR 7 CTS 8 RTS 9 DB 9 F 8 Pin No Signal 1 DSR 2 RTS 3 GND 4 TxD 5 RxD 6 DCD 7 CTS 8 DTR RS 232 RJ45 8 pin C RJ45 DB9M 4 RJ 45 to RS2...

Reviews: