background image

 

614-00051  Rev 00 

 Attero Tech LLC 2018 

IMPORTANT SAFETY INSTRUCTIONS 

 

The symbols below are internationally accepted symbols that warn of potential hazards with electrical products. 

 
This symbol, wherever it appears, alerts you to the presence of un-insulated dangerous voltage inside the enclosure -- voltage that 
may be sufficient to constitute a risk of shock. 
 
This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. 
Please read the manual. 
 

1.

 

Read these instructions. 

2.

 

Keep these instructions. 

3.

 

Heed all warnings. 

4.

 

Follow all instructions. 

5.

 

Do not use this apparatus near water. 

6.

 

Clean only with a dry cloth. 

7.

 

Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce 
heat. 

9.

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the 
other. A grounding type plug has two blades and third grounding prong. The wider blade or the third prong is provided for your 
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10.

 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit 
from the apparatus. 

11.

 

Only use attachments/accessories specified by Attero Tech 

12.

 

Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. 

13.

 

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 

14.

 

Unplug this apparatus during lightning storms or when unused for long periods of time. 

15.

 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 
power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been dropped. 

16.

 

This apparatus shall be connected to a mains socket outlet with a protective earthing connection. 

17.

 

When permanently connected, on all-pole mains switch with a contact separation of at least 3mm in each pole shall be incorporated 
in the electrical installation of the building. 

18.

 

If rack mounting, provide adequate ventilation.  Equipment may be located above or below this apparatus but some equipment (like 
large power amplifiers) may cause an unacceptable amount of hum of may generate too much heat and degrade the performance of 
this apparatus, 

19.

 

This apparatus may be installed in an industry standard equipment rack.  Use screws through all mounting holes to provide the best 
support. 

 

  TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. 

 

Summary of Contents for D16Mio

Page 1: ...Page i 1315 Directors Row Suite 107 Fort Wayne IN 46808 260 496 9668 www atterotech com ...

Page 2: ...lugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by Attero Tech 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus 13 When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 14 Unplug this apparatus during lightnin...

Page 3: ...OUT OF THE USE OR INABILITY TO USE THIS EQUIPMENT EVEN IF ATTERO TECH LLC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT SHALL THE LIABILITY OF ATTERO TECH LLC EXCEED THE PURCHASE PRICE OF ANY DEFECTIVE EQUIPMENT This warranty gives you specific legal rights You may have additional legal rights which vary from state to state Note This equipment has been tested and found to comply ...

Page 4: ...ote 8 2 4 2 Using on a Redundant Network 8 2 4 3 Using on Standalone Network 9 3 Device Operation 10 3 1 Display View Operation 10 3 1 1 Bank Metering Views 10 3 1 2 Channel Metering Views 10 3 1 3 Network Info View 10 3 1 4 Dante Info View 10 3 1 5 Version View 11 3 1 6 No Network 11 3 1 7 Identify 11 3 2 Headphone monitoring 11 3 2 1 Headphone Volume 11 3 2 2 Headphone Mute 11 3 3 Factory Reset ...

Page 5: ...phone amp and a high contrast OLED display to provide quick and detailed feedback for audio confidence monitoring and diagnostics The 24V power supply comes pre mounted to the DM16Mio chassis but there is also support for a secondary external 24V DC supply for optional power redundancy On the network side there is a fully redundant Dante interface utilizing both RJ45 connectors and SFP ports The S...

Page 6: ...he device is detected by Dante Controller of unIFY Control Panel FRONT PANEL 1 Headphone Jack 2 Headphone Mute Indicator 3 Headphone Volume Mute Knob 4 Factory Reset Switch 5 OLED Display 6 Front Panel Nav Knob 7 Monitor Select Switch 8 Device Power Status LED DEVICE FEATURES REAR PANEL 9 Bank A Inputs 1 16 10 Bank B Outputs 1 16 11 SFP port Primary 12 SFP Secondary 13 Ethernet Port Primary 14 Eth...

Page 7: ...he analog audio inputs Attach analog audio destinations to the analog audio outputs The analog audio inputs and outputs are balanced so be sure to check what connection type the source and destination devices use in order to connect it correctly Refer to the following diagrams and instructions for connecting different types of audio devices Note Based on the input source type it will be necessary ...

Page 8: ... configured A Quick Start Guide for AES67 Audio Networking is available from the Attero Tech Customer Portal at https portal atterotech com home v files 560321a2b075c As setup needs may vary by product it may also be necessary to check with the AES67 enabled product manufacturer as well 2 4 2 Using on a Redundant Network The DM16Mio is setup for use in a redundant network out of the box In this mo...

Page 9: ...etwork Note Connecting either secondary port to a standalone Dante network while the D16Mio is still set in Redundant mode will cause problems due to the IP address setup of the secondary ports having completely different IP addresses Therefore this should be avoided Figure 6 Standalone connection in Redundant mode For full flexibility in a standalone network the DM16Mio should be reconfigured to ...

Page 10: ...e knob to select one of the visible channels Once the desired channel is selected press the separate Monitor Select button and that channel will when be routed to the headphone output 3 1 2 Channel Metering Views Each individual input and output channel has its own view The meter itself is shown in the horizontally across the main part of the view from left to right The name of the current channel...

Page 11: ... front panel controls will not operate until the Identify function is disabled 3 2 Headphone monitoring The DM16Mio has a headphone output that can be used to monitor audio signals in the device The currently selected channel for monitoring is shown in the bottom left corner of any of the metering views Selecting a channel can be done from any of the metering views The headphone output has both vo...

Page 12: ... was active the screen will blank releasing the switch after 5 seconds will then start the factory reset process 3 4 Firmware Updates If a firmware update for the DM16Mio is released it may be applied in the field by the end user or installer The update process takes advantage of the smart firmware update tool in unIFY The unIFY Control Panel application is available from the customer portal on th...

Page 13: ...nel mounted headphone jack for monitoring The interface shall have 16 balanced line level outputs available on terminal blocks or DB 25 connectors The output attenuation level shall be configurable in 1 dB increments from 0 to 100 dB The Dante interface shall support a switched or redundant network mode The device shall have two integrated Gigabit Ethernet ports on RJ 45 connectors and 2 gigabit S...

Page 14: ... FCC CFR 47 Parts 15B Class A EN55011 ICES 003 CE EN55022 EN55024 RoHS REACH Environmental Operating Specifications Operating Temperature 0 to 40 C Analog Audio Inputs Input Type 16 Balanced 3 pin line level Terminal Block option 4 TASCAM pinout compatible DB25 balanced analog DB 25 option Input Impedance 10 kΩ Line Mode Maximum Input Levels 24 dBu Pad Active Line Mode 0 005 THD N 0 005 at 3 dBFS ...

Reviews: