background image

 

614-00051  Rev 00 

 Attero Tech LLC 2018 

 LIMITED FIVE YEAR WARRANTY 

 
The equipment is warranted for five years from date of purchase from Attero Tech, LLC against defects in materials or workmanship. This 
warranty does not cover equipment which has been abused or damaged by careless handling or shipping. This warranty does not apply to 
used or demonstrator equipment. Should any defect develop, Attero Tech, LLC will, at our option, repair or replace any defective parts without 
charge for either parts or labor. If Attero Tech, LLC cannot correct the defect in the equipment, it will be replaced at no charge with a similar 
new item. Attero Tech, LLC will pay for the cost of returning your equipment to you. This warranty applies only to items returned to Attero 
Tech, LLC, shipping costs prepaid, within five years from the date of purchase. This Limited Warranty is governed by the laws of the State of 
Indiana. It states the entire liability of Attero Tech, LLC and the entire remedy of the purchaser for any breach of warranty as outlined above. 
NEITHER ATTERO TECH, LLC NOR ANYONE INVOLVED IN THE PRODUCTION OR DELIVERY OF THE EQUIPMENT SHALL BE LIABLE FOR ANY 
INDIRECT, SPECIAL, PUNITIVE, CONSEQUENTIAL, OR INCIDENTAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THIS EQUIPMENT 
EVEN IF ATTERO TECH, LLC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL THE LIABILITY OF ATTERO TECH, 
LLC EXCEED THE PURCHASE PRICE OF ANY DEFECTIVE EQUIPMENT. 
 
This warranty gives you specific legal rights. You may have additional legal rights which vary from state to state. 
 

Note: This equipment has been tested and found to comply with the limits for a Class A 

digital device, pursuant to Part 15 of the FCC Rules and EN55022. These limits are 

designed to provide reasonable protection against harmful interference when the 

equipment is operated in a commercial environment. This equipment generates, uses, 

and can radiate radio frequency energy and, if not installed and used in accordance with 

the instruction manual, may cause harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to cause harmful interference, 

in which case the user will be required to correct the interference at their own expense. 

 

 
 

 
This symbol means the product must not be discarded as household waste, and should be delivered to an appropriate collection 
facility for recycling. Proper disposal and recycling helps protect natural resources, human health and the environment. For more 
information on disposal and recycling of this product, contact your local municipality, disposal service, or the business where you 
bought this product. 

 
 

 

Summary of Contents for D16Mio

Page 1: ...Page i 1315 Directors Row Suite 107 Fort Wayne IN 46808 260 496 9668 www atterotech com ...

Page 2: ...lugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by Attero Tech 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus 13 When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 14 Unplug this apparatus during lightnin...

Page 3: ...OUT OF THE USE OR INABILITY TO USE THIS EQUIPMENT EVEN IF ATTERO TECH LLC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT SHALL THE LIABILITY OF ATTERO TECH LLC EXCEED THE PURCHASE PRICE OF ANY DEFECTIVE EQUIPMENT This warranty gives you specific legal rights You may have additional legal rights which vary from state to state Note This equipment has been tested and found to comply ...

Page 4: ...ote 8 2 4 2 Using on a Redundant Network 8 2 4 3 Using on Standalone Network 9 3 Device Operation 10 3 1 Display View Operation 10 3 1 1 Bank Metering Views 10 3 1 2 Channel Metering Views 10 3 1 3 Network Info View 10 3 1 4 Dante Info View 10 3 1 5 Version View 11 3 1 6 No Network 11 3 1 7 Identify 11 3 2 Headphone monitoring 11 3 2 1 Headphone Volume 11 3 2 2 Headphone Mute 11 3 3 Factory Reset ...

Page 5: ...phone amp and a high contrast OLED display to provide quick and detailed feedback for audio confidence monitoring and diagnostics The 24V power supply comes pre mounted to the DM16Mio chassis but there is also support for a secondary external 24V DC supply for optional power redundancy On the network side there is a fully redundant Dante interface utilizing both RJ45 connectors and SFP ports The S...

Page 6: ...he device is detected by Dante Controller of unIFY Control Panel FRONT PANEL 1 Headphone Jack 2 Headphone Mute Indicator 3 Headphone Volume Mute Knob 4 Factory Reset Switch 5 OLED Display 6 Front Panel Nav Knob 7 Monitor Select Switch 8 Device Power Status LED DEVICE FEATURES REAR PANEL 9 Bank A Inputs 1 16 10 Bank B Outputs 1 16 11 SFP port Primary 12 SFP Secondary 13 Ethernet Port Primary 14 Eth...

Page 7: ...he analog audio inputs Attach analog audio destinations to the analog audio outputs The analog audio inputs and outputs are balanced so be sure to check what connection type the source and destination devices use in order to connect it correctly Refer to the following diagrams and instructions for connecting different types of audio devices Note Based on the input source type it will be necessary ...

Page 8: ... configured A Quick Start Guide for AES67 Audio Networking is available from the Attero Tech Customer Portal at https portal atterotech com home v files 560321a2b075c As setup needs may vary by product it may also be necessary to check with the AES67 enabled product manufacturer as well 2 4 2 Using on a Redundant Network The DM16Mio is setup for use in a redundant network out of the box In this mo...

Page 9: ...etwork Note Connecting either secondary port to a standalone Dante network while the D16Mio is still set in Redundant mode will cause problems due to the IP address setup of the secondary ports having completely different IP addresses Therefore this should be avoided Figure 6 Standalone connection in Redundant mode For full flexibility in a standalone network the DM16Mio should be reconfigured to ...

Page 10: ...e knob to select one of the visible channels Once the desired channel is selected press the separate Monitor Select button and that channel will when be routed to the headphone output 3 1 2 Channel Metering Views Each individual input and output channel has its own view The meter itself is shown in the horizontally across the main part of the view from left to right The name of the current channel...

Page 11: ... front panel controls will not operate until the Identify function is disabled 3 2 Headphone monitoring The DM16Mio has a headphone output that can be used to monitor audio signals in the device The currently selected channel for monitoring is shown in the bottom left corner of any of the metering views Selecting a channel can be done from any of the metering views The headphone output has both vo...

Page 12: ... was active the screen will blank releasing the switch after 5 seconds will then start the factory reset process 3 4 Firmware Updates If a firmware update for the DM16Mio is released it may be applied in the field by the end user or installer The update process takes advantage of the smart firmware update tool in unIFY The unIFY Control Panel application is available from the customer portal on th...

Page 13: ...nel mounted headphone jack for monitoring The interface shall have 16 balanced line level outputs available on terminal blocks or DB 25 connectors The output attenuation level shall be configurable in 1 dB increments from 0 to 100 dB The Dante interface shall support a switched or redundant network mode The device shall have two integrated Gigabit Ethernet ports on RJ 45 connectors and 2 gigabit S...

Page 14: ... FCC CFR 47 Parts 15B Class A EN55011 ICES 003 CE EN55022 EN55024 RoHS REACH Environmental Operating Specifications Operating Temperature 0 to 40 C Analog Audio Inputs Input Type 16 Balanced 3 pin line level Terminal Block option 4 TASCAM pinout compatible DB25 balanced analog DB 25 option Input Impedance 10 kΩ Line Mode Maximum Input Levels 24 dBu Pad Active Line Mode 0 005 THD N 0 005 at 3 dBFS ...

Reviews: