background image

DOC-1000496-A-1 

SPECIFICATIONS 

Relay Max Switch Circuit:

o

5A @ 110-277VAC (+/- 10%)

o

3A @ 347VAC (+/- 10%)

o

2A @ 480VAC (+/- 10%)

Dim Control Max Load: 20mA

Radio Frequency: 2.4 GHz (IEEE 802.15.4)

RF Transmission Output Power: +20dBM

Operating Temperature: -40 to +70 C

Operating Humidity: 0 to 90%, non-condensing

Dimensions: 3.3” D x 3.9” H

(84mm D x 98mm H) 

Surge Protection: 6kV

Sensor Input: 24V

Sensor Power Max Load: 24VDC @ 20mA

CAUTION 

This product must be installed in accordance with
national, state, and local electrical codes and
requirements

All work must be performed by qualified personnel

Disconnect all power before installation or service

WIRING DETAILS OF C136.41 SOCKET 

WARNING: TO AVOID FIRE, SHOCK, OR DEATH: 

TURN OFF POWER

 AT CIRCUIT BREAKER OR FUSE 

AND VERIFY THAT POWER IS OFF BEFORE WIRING! 

If a motion sensor or the C136.41 socket needs to be 
wired up prior to installing the TL7-HVG,  please refer 
to the wiring details. 

(See Figure 1) 

 

 

 

 

 

WARNING AND CAUTIONS: 

TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER

 AT CIRCUIT BREAKER OR

FUSE AND TEST THAT POWER IS OFF BEFORE INSTALLING! 

The TL7-HVG should only be installed in a fixture with a NEMA/ANSI C136.41 receptacle. 

Device is rated up to 6kV surge, take steps to install an external surge protector for

additional protection.

Failure to follow these instructions and warnings could potentially void warranty.

TL7-HVG Lighting Controller 

Load Rating: 110-480VAC ±10% 

 

WARNING AND CAUTIONS:

 

To be installed and/or used in accordance with appropriate electrical codes and 

regulations. 

If you are unsure about any part of these instructions, consult an electrician; all work 

should be performed by qualified personnel. 

Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture 
or changing lamps. 

INSTALLATION GUIDE 

 

Figure 1 – C136-41 Socket Wiring Details 

Reviews: