 CONNECTION

Connectors

The Syncro ADC Encoder 12x features these connectors:

CN1 POWER SUPPLY 2-pin Connector

1 blue 0V AC (N)

2 black 230V AC (L)

CN2 DMX IN 3-pin connector

1 grey GND,Shield

2 blue DMX -

3 orange DMX +

CN3 DMX OUT 3-pin connector

1 grey GND, Shield

2 blue DMX -

3 orange DMX +

CN4 ANALOG IN 20-pin connector

1 Analog input 1

2 Analog input 2

3 Analog input 3

4 Analog input 4

5 Analog input 5

6 Analog input 6

7 Analog input 7

8 Analog input 8

9 Analog input 9

10 Analog input 10

11 Analog input 11

12 Analog input 12

13 nc

14 nc

15 nc

16 nc

17 Shield, 0V, GND

18 Shield, 0V, GND

19 +5V stab out

20 +10V DC stabilized out

CN5 START ADDRESS 10-pin connector

Connector to connact a start address board 3000P or 3003P for start address and device properties pro-

gramming. Unit may be used with or without start address board attached.

Summary of Contents for SyncroADC

Page 1: ...SyncroADC Operating Manual www syncronorm com info syncronorm com liquidinspiration...

Page 2: ...real time 3D visualizer Our dynamic experienced team thereby operates on a world wide scale providing you with the best software hardware solutions fitting to your dedicated project From show design...

Page 3: ...DC accepts 12 analog Inputs It is ideally suited to integrate operating Panels or analog inputs into the Syncronorm Depence Network Structure The unit may be configured for linear Mode to switching mo...

Page 4: ...lping you to use the unit correctly and effectively Adhere to all instructions contained in this manual when installing and operating this unit Every person working with this equipment must read this...

Page 5: ...y instructions are ignored This unit must not be used by children under the age of 18 Persons with impairments or lack of experience and knowledge may use the unit as long as they are supervised and i...

Page 6: ...n personnel have the required technical qualifications Also ensure that all operating personnel are sufficiently qualified Ensure that maintenance work is only performed by personnel authorized for th...

Page 7: ...ensure that all maintenance inspection and installation work is car ried out by authorized and qualified personnel who have read and understood this manual Only carry out maintenance work on this uni...

Page 8: ...connector 1 Analog input 1 2 Analog input 2 3 Analog input 3 4 Analog input 4 5 Analog input 5 6 Analog input 6 7 Analog input 7 8 Analog input 8 9 Analog input 9 10 Analog input 10 11 Analog input 1...

Page 9: ...oards cat no 3000P switches or 3003P display may be used Since one start adress board can be used to program any DIN rail unit this is NOT contained with this product and must be ordered separately 0...

Page 10: ...last valid settings will be retained in nonvolatile memory Note It may take about 2 secs until data are saved The input DMX signal is fed to the DMX512 output and is superimposed with the analog inpu...

Page 11: ...an Waste Electrical and Electronic Equipment Directive WEEE FCC Statement This product has been tested and complies with the specifications for a Class B digital device pursuant to Part 15 of the FCC...

Page 12: ...t to complaint Claims the origin of which can be traced back to installation and operating faults as well as lack of care e g the use of unsuitable cleaning materials or negligent maintenance use othe...

Page 13: ......

Reviews: