background image

Step 3. Usage & operation 

< Details > 

provides a detailed status about a certain PDU. The user can not only set the name &  

                   location for PDU & each outlet, but also power ON / OFF the outlets one by one for  

                   switched PDU.

P.17

Summary of Contents for InfraPower IPM-01

Page 1: ...Toll Free 1 888 865 6888 Tel 510 226 8368 Fax 510 226 8968 Email sales RackmountMart com...

Page 2: ...User Manual IPM 01 PDU management software MTS switched PDU MT monitored PDU Intelligent Remote Power Management...

Page 3: ...ve it checked by qualified service personnel What the warranty does not cover Any product on which the serial number has been defaced modified or removed Damage deterioration or malfunction resulting...

Page 4: ...M4 x 2 M6 x 2 M6 nut x 2 PEG OUT IN RES ET ON DIP 1 8 7 6 5 4 3 2 CUR REN T A 225 M4 M4 M6 M6 M6 nut M6 nut Bracket x 2 2 Rackmount MTS MT PDU x 1 OR Power ON Connect the PDU into an appropriately ra...

Page 5: ...configuration 2 2 InfraPower Manager IPM 01 FREE PDU management software Part III Data Export Part IV FAQ 4 1 InfraPower Manager IPM 01 4 2 IP dongle 4 3 Meter for MTS MT PDU 4 4 Others Part V Trouble...

Page 6: ...Off On On Off 5th level PDU On On Off On Off 6th level PDU Off On Off On Off 7th level PDU On Off Off On Off 8th level PDU Off Off Off On Off 9th level PDU On On On Off Off 10th level PDU Off On On O...

Page 7: ...N DIP 7 6 5 4 3 2 1 8 ON DIP 7 6 5 4 3 2 1 8 P 2 Up to 20 meters Up to 20 meters The PDU can be cascaded up to 16 levels For IP PDU access simply connect 1 x IP dongle IPD 01 1 x IP dongle allows acce...

Page 8: ...he LINK port of the 1st level PDU meter use the CAT 5 6 cable to connect IP dongle to network device To LINK port of the 1st PDU To LAN port CAT 5 6 cable CAT 5 6 cable Up to 20 meters Up to 20 meters...

Page 9: ...ount PDU with 4 screws plug the RJ 45 connector of IP dongle into the LINK port of the 1st level PDU meter use the CAT 5 6 cable to connect IP dongle to network device To LINK port of the 1st PDU Cust...

Page 10: ...5 6 cable 4 Click Scan to search the connected IP dongles 5 Enter the device name in the name field min 4 char max 16 char The default is Name 6 Enter the location in the location field min 4 char ma...

Page 11: ...ownload Prepare a management PC to download the free InfraPower Manager IPM 01 from the link http www rackmountmart com support software infrapower IPM 01 msi Supported OS platform list MS Windows XP...

Page 12: ...Step 1 Software download P 7 IPM 01 msi Double click the IPM 01 msi and follow the instruction to complete the installation...

Page 13: ...Step 1 Software download P 8...

Page 14: ...ator rights before execution Right click InfraPower Manager IPM 01 and then select Properties Click the Compatibility tab Tick the box Run this program as an administrator and then click OK Double cli...

Page 15: ...n be changed by user The password of PostgreSQL must contain at least three of the following four character groups English uppercase characters A through Z English lowercase characters a through z Num...

Page 16: ...nto the address bar If fail to access please ask MIS to check the service port of the management PC Step 3 Enter the user name the default is admin Enter the password the default is 00000000 Users can...

Page 17: ...Step 2 System setup In Setup page the administrator can activate the IP dongle group set the group command password P 12...

Page 18: ...Step 2 System setup Alarm P 13 example...

Page 19: ...Refresh Step 2 System setup Scan Backup SNMP P 14...

Page 20: ...log provides last 5000 event occurrences in user setup alarm scan refresh backup SNMP P 15 Past sys log provides a search function in a certain period to find event occurrences in user setup alarm sc...

Page 21: ...Step 3 Usage operation Status provides the users a scan function to monitor the PDUs of each IP dongle group one by one set the alarm amp for the PDU P 16...

Page 22: ...3 Usage operation Details provides a detailed status about a certain PDU The user can not only set the name location for PDU each outlet but also power ON OFF the outlets one by one for switched PDU...

Page 23: ...Step 3 Usage operation PDU log provides last 5000 PDU log records about a certain PDU by the user s selection The software will generate a PDU log record in every one minute P 18...

Page 24: ...Step 3 Usage operation Event provides last 5000 events occurrences about PDU s configuration connection in a certain IP dongle group P 19...

Page 25: ...P 20 Step 3 Usage operation Past log provides a search function in a certain period to find the log records about a certain PDU or the event occurances about a certain IP dongle group Completed...

Page 26: ...box of PDU log ignore the PDU level selection 3 Enter the period of PDU log to export min 1 day max 31 days 4 Click Export and a Message from webpage dialog box pops up 5 Click OK to confirm the expo...

Page 27: ...P 22 6 Right click the PDU level below 7 Select Save Target As to download the PDU log file...

Page 28: ...P 23 8 Select the path click Save to complete the download process Please take Step 6 7 8 for the other PDU levels one by one...

Page 29: ...P 24 Below is the sample of a PDU log file in MS Excel CSV format User can use the data for analysis purpose Completed...

Page 30: ...tion and execution 3 Which database does the IPM 01 support PostgreSQL 4 What is the PostgreSQL default password for IPM 01 1qaz2WSX 5 How can I receive alarm email and get full log report Ensure that...

Page 31: ...onfiguration Protocol No the IP dongle only works with static IP address 4 How can I reset the IP dongle password to the factory default value Press the reset button of IP dongle for at least 8 second...

Page 32: ...e MTS PDU supports IEC 60320 C13 IEC 60320 C19 NEMA 5 15 20R BS1363 outlet type 4 Can the MTS and MT PDUs cascade together Yes the MTS MT model PDUs can connect together as a cascade chain 5 If one of...

Page 33: ...nected PDU to check if the problem caused by the first disconnected PDU 3 GUI shows the whole group of PDU s disconnected Step 1 Cable disconnected loose or defective Check the Cat 5 6 cable connectio...

Page 34: ...U Step 7 Power on the new PDU and connect to the device s Step 8 Click Start Connection in Status page for the relevant IP dongle Step 9 Configure the new PDU in Status and Details page such as Alarm...

Page 35: ...re and reset the level for the affected PDU s which next to the removed PDU Ignore step 1 3 if the removed PDU is in the last level 5 How to add an extra PDU to an existing PDU group Step 1 Prepare a...

Page 36: ...ations without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Co...

Reviews: