NO.2
NO.1
NO.3
90°
NO.3 Back Check
NO.1 Closing
NO.2 Latching
Power Adjustment
Arm is fitted in pinion with hex head screws.
1
2
3
4
5
Using the templates provided, mark and drill pilot
holes into the door and frame.
Attach the armset to the mechanism ensuring
the pre-loading requirement has been completed.
Using the templates provided, fix the mechanism to the door
as well as the armset and any necessary brackets.
Backcheck Adjustment
To increase the backcheck action, turn the valve clockwise. To decrease, or to turn
off backcheck , turn the valve counter clockwise.
Adjust the Closing & Latching speed.
1.The door closer can control two different speeds.
2.The No.1 speed-adjusting valve controls the Closing speed, and the No.2 speed
adjusting valve controls the Latching speed.
Operate door closer in order to check operation.
Regular Fixing
Installation and Maintenance Instructions:
Maintenance
1.Once the unit has been correctly
fitted it is recommended that
periodic checks (every six
months) are carried out to ensure
all fixings are tight and the door
closes freely and positively into
the frame, without slamming.
2.A light oil lubricant (non-graphite)
should be applied to the moving
joints and exposed pivot points.
After Installation
1.When the closer operates to close
the door from its maximum opening
position, it should ensure the lock
latchbolt and any seals are overcome
and the leaf returned into its frame.
2.When the door is slightly open and
the latch bolt resting against the
strike, release the door to ensure the
leaf fully closes into its frame.
Warning
1.Please note the minimum power size requirement for fire / smoke
door assemblies is 3 as required by Approved Document B.
2.Do not install mechanical hold open devices on fire / smoke door
assemblies.
3.Take care not to exceed the maximum opening angle as detailed
above.
4.Care and attention must be taken when adjusting any of the units
control valves to avoid damage through over adjustment.
5.All Synergy Door Closer units are sealed for life and the internal
components assembled under high load, therefore, tampering
with the mechanism is to be strictly avoided.
Installation Instructions: Please refer to actual size template for exact fitting dimensions
Pre-Loading of Arm
For the unit to provide the optimum performance and overcome
any resistance upon closing it is recommended that the armset
is “pre-loaded” To pre-load, reposition the fixing angle of the
arm onto the mechanism so that the end of the closing cycle
would be past the stop position, as indicated below.
Adjustment Details
This unit is a power adjustable mechanism. Power / force adjustment is carried out by a single
adjustment valve in the end of the mechanism. The unit is pre-set in the factory at EN size 3.
Please see table below for adjustment details for each power size.
The following adjustment valves have a maximum adjustment of 1 full turn per valve.
PLEASE
NOTE
over adjustment will damage the mechanism and/or the performance of the door closer and
invalidate its guarantee.
Adjust Backcheck (valve #3) before
adjusting the Closing Speed (valve #1) and
Latching Action (valve #2).
90°
90°
Before
After
ISSUE 01:03/19
10803 ZINS-FA1289-3S
www.synergyhardware.co.uk
Fixing Instructions for
S900 Series
Door Closer
Power Adjustable EN 2-6
APPROVED
PRODUCT
CF5294
CPR
AD5330
1121
17
BS EN1154:1997+ A1:2002
4 8 62 1 1 3
www.synergyhardware.co.uk
Fixing in Fig.1
Force Max. door
width
Max. door
weight
Max.
opening
angle
Number
of turns
Direction
FACTORY PRE-SET
0
0~+3
+3~+6
+6~+9
+9~+12
Clockwise
Clockwise
Clockwise
180°
180°
180°
180°
180°
850mm
950mm
1100mm
1250mm
1400mm
40kg
60kg
80kg
100kg
120kg
2
3
4
5
6
+
-
SW5
SLOW
FAST