he Blade Inline DHP System is an electrical device. Please read, understand, and follow all safety 

instructions and considerations in this manual prior to use of your Blade Inline DHP System. Retain 
these instructions for future reference and take all necessary precautions to reduce the risk of fire, 
electric shock, explosion, or injury.  

The DHP Limited Warranty applies only if the unit is used in accordance with these instructions.  
Only use genuine Synexis parts and sails to ensure the proper functioning of your unit and to maintain 
your warranty.

 

All HVAC, Electrical, Bulb, and Sail replacement must be performed by a qualified technician.

 

It is recommended that a switch be installed to de-energize the Blade Inline unit for service and  

 maintenance. 

 

Wire the Blade Inline unit in accordance to NEC standards, NFPA standards & local electrical  

 

code for 120 VAC/60 Hz power (for US). If you are uncertain how to properly wire the device,  

 

please consult or contract a qualified electrician. 

 

This device is designed for a closed duct system. Do not mount it near a return air opening. 

 

This device is designed for indoor installation only (i.e. attics, basements, etc.). It is for use in  

 

the duct work of gas fired, oil fired, electric and split system heat pump forced air systems. It  

 

is NOT designed to be mounted outside on gas fired or heat pump packaged units. 

•  Split system heat pumps are systems where the air handler and the air conditioning  

 

compressor are separate units. 

•  Packaged units are systems where the air handler and air conditioning compressor are  

 

built together and installed outside the building.

 

Do not touch the electrical components with wet hands. 

 

Do not use outdoors or in a wet environment. This device is for indoor, dry location use only.  

 

Do not submerge the Blade Inline system in water. 

 

To prevent water damage or electric shock, do not mount this device under a humidifier. 

 

Do not use any combustible or flammable items on or near the Blade Inline system. 

 

Do not spill or spray any liquids or aerosols into the Blade Inline system or on the DHP  

 

Technology Sail.  

 

Do not place the Blade Inline system near a heat source. 

 

Do not modify or attempt to modify this product.

Summary of Contents for Blade Inline

Page 1: ...1 www synexis com 1 844 352 7680 OWNERS MANUAL BLADE INLINE SYNEXIS SYSTEM www synexis com 1 844 352 7680 ...

Page 2: ...al and continuous reduction of microbial contamination in occupied spaces Our microbial reduction systems are patented for use in the United States and around the world By encompassing all areas of an enclosed space DHP can reach the most important areas of a facility The critical differentiator of DHP from other forms of hydrogen peroxide is that DHP can be safely delivered in occupied spaces Usi...

Page 3: ...om the use of information contained herein This Blade Inline manual is provided as is and without any representation term condition or warranty of any kind either express or implied To the extent permitted by law Synexis shall not be liable to any person or entity for any loss or damage which may arise from the use of this manual We reserve the right at any time and without any notice to remove am...

Page 4: ...e Blade Inline DHP System Familiarize yourself with the installation steps and required tools Inspect your system and parts Please contact your Account Representative for questions or additional information Included Parts Blade Inline unit x1 UV A Light Bulb x1 DHP Technology Sail x1 sealed in plastic and sold separately Sail Holder Self Tapping Sheet Metal Mounting Screws x8 Mounting Template x1 ...

Page 5: ...he Blade is a completely discreet option for deploying Dry Hydrogen Peroxide DHP in your occupied environment Device installation will not impact your existing HVAC system Specifications Weight 5 lbs Material 18 Gauge Stainless Steel Color Stainless Steel Dimensions Width 8 6 21 84 cm Height 10 9 27 69 cm Depth 6 8 17 27 cm Electrical Requirements Input Voltage 120 VAC 60 Hz US Current 56 Amps ...

Page 6: ...al Support for guidance Prior to Installation To ensure optimal performance inspect ductwork prior to installation Clean diffusers and ductwork Proper level of airflow with no obstructions Dampers not located upstream within six feet of the Synexis system Dampers not located downstream between the Synexis system and diffuser Tools for Installation Hole saw or step bit Tin snips or sheet metal shea...

Page 7: ...a qualified electrician This device is designed for a closed duct system Do not mount it near a return air opening This device is designed for indoor installation only i e attics basements etc It is for use in the duct work of gas fired oil fired electric and split system heat pump forced air systems It is NOT designed to be mounted outside on gas fired or heat pump packaged units Split system hea...

Page 8: ...es so it is important to keep all external windows and doors closed as much as possible Open windows and or doors can significantly reduce the efficiency of your system by allowing the DHP to dissipate out of the facility Continuous operation 24 7 365 The Synexis Blade Inline DHP system is designed to operate 24 hours a day 7 days a week DHP is meant to be a continuous clean technology as opposed ...

Page 9: ...sired for the installation Remove the Cut Out Area of the template Drill the 1 8 inch diameter holes where indicated on the template Trace the Cut Out Area with a marker and remove the template Ensure that the bulb is centered with respect to the sail frame Utilizing a step drill bit drill a hole within the area of the duct to be removed Remove the remaining section of sheet metal from the Cut Out...

Page 10: ... is designed so that the sail can only be inserted in the correct orientation or the push rivets will not line up Mount the unit base to the duct using the eight 8 mounting screws provided Wire the recommended switch and ballast using 120 VAC for US Check with NEC standards NFPA standards and local electrical codes for the required wire type size and connectors Replace the electrical box cover and...

Page 11: ...e bulb out carefully Install replacement bulb Gently push the bulb up until seated in the socket Always wipe off the newly installed bulb to remove any oil or debris WARNING UV A bulbs contain a small amount of mercury like a typical fluorescent bulb Check with your local waste management authority for local disposal or recycling requirements Additional disposal and recycling information can be fo...

Page 12: ... food grade plastic bag to keep it fresh until your Synexis Blade Inline DHP system is installed and ready for the sail to be inserted For best performance only handle the outer plastic frame of the sail Do not remove the sail from the opaque plastic bag until it is ready to use in the system The sail can be disposed of as simple trash or as recyclable plastic frame and polyester fabric No special...

Page 13: ...d the electrical breaker if there is no power to the ballast If the bulb still doesn t light up using a voltmeter verify that the ballast is generating an electrical signal to the bulb If there is no electrical signal going to the light bulb replace the ballast If the bulb still doesn t light up replace the bulb If problems persist contact Synexis technical support between the hours of 8 AM 5 PM C...

Page 14: ...number Distributor Info Distributor address Date of purchase Telephone Warranty Contact your Account Representative for any device questions service material needs or device issues When contacting Synexis for a system issue that is under warranty please be prepared to provide the following The unit and distributor info above A copy of the bill of sale Invoice or receipt of purchase An explanation ...