Section III
Operation
006-0006504 02/27/18
Rev R
29 of 56
UPS-3000 Guide
www.synqor.com
Operating Environment
The SynQor UPS-3000 Series is designed for the extreme environmental conditions of military
and aerospace applications. All the electronic circuitry and the battery packs are contained
in a sealed, weather-proof, shock-proof chamber constructed of die-cast aluminum. Only the
redundant, water-proof cooling fans are exposed to the environment. Protection circuitry
ensures that the batteries are not charged or discharged if it is too hot or too cold. The UPS will
shut down if it is too hot.
The UPS (with cables connected or connector covers installed and the battery packs installed)
has been qualified to the following requirements of MIL-STD-810G:
MIL-STD-810G
Test Method
Name
Procedure
Details
500.5
Low Pressure
I, II and III
▪ 18,000 ft. operating
▪ 40,000 ft. storage
501.5
High Temperature
I and II
▪ +55
o
C operating
▪ +65
o
C storage
502.5
Low Temperature
I and II
▪ -20
o
C operating
▪ -40
o
C storage
503.5
Temperature Shock
I
▪ 12 cycles; -40
o
C to 65
o
C
506.5
Rain
I
▪ 4” rain/hour
▪ 40 mph wind velocity
507.5
Humidity
II
▪ >95%
508.6
Fungus
NA
▪ 28 day test
509.5
Salt Fog
NA
▪ 5% salt solution
▪ 2 cycles (24 hr wet/24 hr dry)
510.5
Sand and Dust
I and II
▪ 20 mph blowing dust
▪ 40 mph blowing sand
514.6
Vibration
Category 5
▪ 5 Hz (300 RPM)
▪ Loose Cargo
Vibration
Category 24
▪ PSD = 0.04 g
2
/Hz; 20-2000 Hz
▪ Operating
516.6
Shock
I, IV and VI
▪ 20 g/11 ms; 40 g/sawtooth
▪ 48 inch drop in transit case
▪ 45 degree tilt and drop
528
Mechanical Vibrations of
Shipboard Equipment
I
▪ Operating