3
screwdriver counterclockwise will widen the air gap (increasing the current draw).
To adjust the air gap to a proper setting, turn the knob on the front of the jogger to a "100" dial setting. Then
turn the core clockwise until a striking condition exists, then immediately turn the screwdriver counterclockwise,
just until the striking stops.
Check the current draw of the jogger using an a-c ammeter. If a clamp-on type ammeter is used the reading
must be multiplied by 1.7. Do not exceed a current draw of 1.0 amps.
When the proper air gap has been achieved (indicated by the current draw), lock the core in place by turning
the socket head cap screw on the bottom of the jogger. The jogger is now ready for further operation.
TROUBLE SHOOTING
PROBLEM
CAUSE
CORRECTION
Unit does not operate
Defective control board
* Replace
Shorted wiring, loose
Repair
connection, no power to unit
Unit operates, will not
Defective Control Board
*Replace
vibrate
Defective leaf springs
*Replace
Unit In contact with rigid
object or adjacent surface
Isolate unit
Excessive noise
Armature and magnet
Adjust air gap
assemblies making contact
*Replace only with parts supplied, or recommended, by Syntron Material Handling, LLC.