7.2.3 Check / Exchange Solenoid Valve
Remove the John-Guest angle by pushing-in the angle´s grey ring with
two fingers and using the other hand to remove the angle.
Remove the second John-Guest angle ,which leads into the salt con-
tainer, in the same way.
We recommend to pull the cabinet slightly forward.
Remove the connections.
Remove both screws of the solenoid valve´s fixing bracket.
Remove two further screws from the fixing bracket.
Once the solenoid valve is unscrewed from the fixing bracket, it can
be replaced.
Re-assemble in reversed order.