Device
Functions
©
SYS TEC electronic GmbH 2007 L-1032e_9
29
<alive> ::= alive:<num>
0
switches off the cyclical testing of the communication
paths. An absence of communication parameters is not
recognized, the effected interface must then be removed
manually.
1
turns on the cyclical testing of the command paths
(default for UDP). Not available for TCP interface
<reco> ::= reco:<num>,[<time>]
0
switches off the automatic reconnection function
1
switches on the automatic reconnection function (default)
time
number of seconds waited until a new connection is
attempted (default: 120)
<trig> ::= trig:<cnt>[:<time>]
These parameters can be used to control the transmission of CAN
telegrams within TCP/UPD packets. A trigger threshold is set
which enables a specified minimum number of CAN messages to
be transmitted in a single UDP/TCP packet. In order to make sure
that the packets are transmitted after a maximum time, even if the
minimum number of CAN telegrams has not be reached, an
additional timer event can initiate the transmission of the
UDP/TCP packets. These parameter are applicable for
connections, which are established automatically over this
UDP/TCP server.
cnt
number of CAN messages which have to at least be
present in the internal buffer for transmission via Ethernet
before an Ethernet packet is sent
value range: 1 - 127
default:
1
time
time in milliseconds [ms] that can have passed since the
last transmission before the next Ethernet packet is
transmitted.
value range:
0 - 4294967295 [ms]
default:
0
Summary of Contents for GW-003
Page 5: ...Contents SYS TEC electronic GmbH 2007 L 1032e_9 Index 97 ...
Page 8: ...CAN Ethernet Gateway SYS TEC electronic GmbH 2007 L 1032e_9 ...
Page 14: ...CAN Ethernet Gateway 6 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Page 56: ...CAN Ethernet Gateway 48 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Page 66: ...CAN Ethernet Gateway 58 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Page 100: ...CAN Ethernet Gateway 92 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Page 108: ...Published by SYS TEC electronic GmbH 2007 Ordering No L 1032e_9 Printed in Germany ...