CAN – Ethernet Gateway
30
©
SYS TEC electronic GmbH 2007 L-1032e_9
The following conditions apply for transmitting a UDP/TCP
packet:
Number of received CAN telegrams >=
cnt
OR
time difference between the last transmission time and the current
time >
time
Output of the current configuration
/if/udp0
↵
Usage: udp0 [to:<ipaddr>[:<port>]] [on|auto|off]
[alive:<num>] [reco:<num>[,<time>]]
[trig:<cnt>[,<time>]]
0 frames sent, 0 frames recv'd, state: Connection
establishment in process
Current settings: to:192.168.10.118:8234 alive:1
reco:1,120 trig:1,0