Configuration
©
SYS TEC electronic GmbH 2007 L-1032e_9
49
5
Gateway Configuration
5.1
Fundamentals
Configuration of the CAN-Ethernet Gateway can be accomplished in
two ways; using the RS-232 interface with a terminal program
(refer
to section
3.5.2)
or a Telnet connection over the Ethernet connection
(refer to section 3.5.3).
The CAN-Ethernet Gateway is configured via configuration scripts.
There are the following two configuration scripts:
/stdrc
Standard
configuration,
- it is fixed in the firmware;
- is executed if the switch "DEFT" is set to ON or if no
/save/rc
exists
or if an error has been detected in the EEPROM or if a
firmware update has been performed
- it contains the following entries:
siocfg 9600
ipcfg 192.168.10.111 255.255.255.0
192.168.10.1
mkif led
/if/led0/fin +l +hd1
mkif can
mkif udpserv
mkif tcpserv
/if/can0 baud:0 canid:fe on
The CAN-Ethernet Gateway is in a passive state and
waits for connection queries following a start with the
standard configuration.
/save/rc
customer specific configuration;
- can be established with the commands
write
and
sync
and is saved in EEPROM
- is executed if the switch "DEFT" is set to OFF
- is established by the customer based on the application
requirements
Summary of Contents for GW-003
Page 5: ...Contents SYS TEC electronic GmbH 2007 L 1032e_9 Index 97 ...
Page 8: ...CAN Ethernet Gateway SYS TEC electronic GmbH 2007 L 1032e_9 ...
Page 14: ...CAN Ethernet Gateway 6 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Page 56: ...CAN Ethernet Gateway 48 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Page 66: ...CAN Ethernet Gateway 58 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Page 100: ...CAN Ethernet Gateway 92 SYS TEC electronic GmbH 2007 L 1032e_9 ...
Page 108: ...Published by SYS TEC electronic GmbH 2007 Ordering No L 1032e_9 Printed in Germany ...