User can inactive call buttons on the transmitter-charging dock when there are
lost or not in use pagers.
3-8. Call Button ON/OFF [Setting code: 664242]
2. Press 6-6-4-2-4-2 to enter the call button
on/off setting mode.
3. Press the call button that is to be turned off.
It turns back on when you press it again.
LED light on the call button will turn on/off
accordingly.
4. Press and hold 6 to save and return to
previous menu.
1. Press and hold 5 for about 10 seconds and
the device becomes input standby mode
(Press and hold until it makes “Beep~~” noise)
## The call button on/off status is indicated with LED for about 1 second as soon as the power is supplied.
3-9. Pager Vibration Intensity [Setting code: 664243]
User can set the vibration intensity level from 1 to 5.
2. Press 6-6-4-2-4-3 to enter the vibration
intensity setting mode.
3. Press the applicable call button to set the vibration intensity.
4. Press 6 to save and return to previous menu.
1. Press and hold 5 for about 10 seconds and
the device becomes input standby mode
(Press and hold until it makes “Beep~~” noise)
6
Save & exit
1
2
3
4
5
Button
Setting value
4
1(Weak)
2
3(Mid)
5(Strong)