background image

User can inactive call buttons on the transmitter-charging dock when there are

lost or not in use pagers.

3-8. Call Button ON/OFF [Setting code: 664242]

2. Press 6-6-4-2-4-2 to enter the call button 
     on/off setting mode.

3. Press the call button that is to be turned off. 

     It turns back on when you press it again. 

     LED light on the call button will turn on/off 

     accordingly.

4. Press and hold 6 to save and return to
     previous menu.

1. Press and hold 5 for about 10 seconds and
     the device becomes input standby mode
    

(Press and hold until it makes “Beep~~” noise)

## The call button on/off status is indicated with LED for about 1 second as soon as the power is supplied.

3-9. Pager Vibration Intensity [Setting code: 664243]

User can set the vibration intensity level from 1 to 5.

2. Press 6-6-4-2-4-3 to enter the vibration 
     intensity setting mode.

3. Press the applicable call button  to set the vibration intensity.

4. Press 6 to save and return to previous menu.

1. Press and hold 5 for about 10 seconds and
     the device becomes input standby mode
    

(Press and hold until it makes “Beep~~” noise)

6

Save & exit

1

2

3

4

5

Button

Setting value

4

1(Weak)

2

3(Mid)

5(Strong)

- 9 -

1

2

3

4

5

6

2

2

4

4

6

6

1

2

3

4

5

6

1

2

3

4

5

6

1

2

3

4

5

6

3

2

4

4

6

6

1

2

3

4

5

6

Summary of Contents for Nttworks GP-206RT

Page 1: ...User Manual Please read the user manual carefully before start using the device User Manual GP 206RT 1 3 4 5 6 2 ...

Page 2: ...ger Number Setting 7 3 5 Other Settings 7 3 5 1 Pager Alarm Type Setting 7 3 5 2 Anti Theft Out Range Setting 8 3 6 Exit from Settings 8 3 7 RF Test Mode 9 3 8 Call Button ON OFF 10 3 9 Pager Vibration Intensity 10 3 10 Call Button Selection 11 3 11 Transmission Output Setting 11 3 12 Initialization 12 4 How to Use GP 206RT 12 4 1 Call a pager 12 4 2 Attend to a call 12 2 ...

Page 3: ...P 206T Frequency Power source Antenna type Dimension Weight Color FSK 433MHz DC 8V 3A SMA type W140 x L149 x H40 mm 120g Black 2 Getting Started Plug the power at the rear of the transmitter charging dock and connect the antenna Rear of the transmitter charging dock Antenna connector Power connector Call button Insert all pagers into the transmitter charging dock in order to start charging The Red...

Page 4: ...it Save exit Save exit Save exit Setting Menu Code Number key Warning All pagers should be placed on the transmitter charging dock while setting Press and hold 5 for about 10 seconds and the device becomes input standby mode Press and hold until it makes Beep noise If you do not touch any key buttons for more than 25 seconds it is automatically exited from the settings 3 Settings 3 1 Channel Numbe...

Page 5: ...etting value 8 1 2 4 16 Save exit 2 Press 6 6 4 2 3 2 to enter the group number setting mode ex Set group number 16 press 5 1 Press and hold 5 for about 10 seconds and the device becomes input standby mode Press and hold until it makes Beep noise 5 2 Press 6 6 4 2 3 1 to enter the channel number setting mode 3 Pick one channel number from 1 to 31 and then press 6 to save and return to previous men...

Page 6: ...sec 1 5 2 10 3 20 4 40 5 1 Press and hold 5 for about 10 seconds and the device becomes input standby mode Press and hold until it makes Beep noise Pager registration 3 4 Pager Number Setting Setting code 664234 2 Press 6 6 4 2 3 4 to enter the pager number setting mode 1 Press and hold 5 for about 10 seconds and the device becomes input standby mode Press and hold until it makes Beep noise 1 2 3 ...

Page 7: ... 2 Press 6 6 4 2 3 5 to enter the other setting mode 3 User can press 1 for vibration and 2 for sound LED cannot be turned off Default Vibration Sound LED 1 2 3 4 5 6 Vibration Button Setting value Sound LED Save exit 4 Press 6 to save and return to previous menu 1 Press and hold 5 for about 10 seconds and the device becomes input standby mode Press and hold until it makes Beep noise 3 Press the n...

Page 8: ... Range function Alert on Pager Sound 3 7 RF Test Mode Setting code 664241 User can verify the channel number Pn group number Gn and the call number of the pager when the RF test mode is on 2 Press 6 6 4 2 4 1 to enter the RF test mode 3 When the RF test mode turns on the relevant number displays in the order of call number of the pager frequency FND test version info Gn and Pn 1 Press and hold 5 f...

Page 9: ...ss and hold until it makes Beep noise The call button on off status is indicated with LED for about 1 second as soon as the power is supplied 3 9 Pager Vibration Intensity Setting code 664243 User can set the vibration intensity level from 1 to 5 2 Press 6 6 4 2 4 3 to enter the vibration intensity setting mode 3 Press the applicable call button to set the vibration intensity 4 Press 6 to save and...

Page 10: ...de Press and hold until it makes Beep noise 6 Save exit 1 2 3 4 5 Button Setting value 1 6 7 12 4 Press 6 to save and return to previous menu User can set the transmission output level from 1 to 5 3 11 Transmission Output Setting Setting code 664251 2 Press 6 6 4 2 5 1 to enter the transmission output setting mode 3 Press the applicable call button to set the output level 1 Press and hold 5 for ab...

Page 11: ... and hold 5 for about 10 seconds and the device becomes input standby mode Press and hold until it makes Beep noise 11 4 How to Use GP 206RT 4 1 Call a pager 4 2 Attend to a call Take one of the pager off from the transmitter charging dock Return the pager to where the pager is given when the pager starts buzzing Place the pager back to the transmitter charging dock to recharge Press the pager num...

Page 12: ...ALL France www syscallglobal fr 0033 0 1 84 17 61 81 contact syscall fr 242 boulevard de Stalingrad 94500 Champigny sur Marne France Manufacturer NTTWORKS CO LTD 413 9 NTTWORKS Bldg Galhyun Dong Eunpyong Gu Seoul Korea ...

Reviews: