3
Installation Description
3.1
Mounting
3.1.1
TFT/HBxxxPU8yyy-zzzz
Mounting the device requires the following steps:
1.
The desired mounting place must have a cut out and wall thickness regarding the following overview.
Front cut out dimensions
Edge radius
Wall thickness
Device #
W [mm]
H [mm]
R [mm]
D [mm]
TFT/HB104PR8yyy-zzzz
271
-0/+2
217
-0/+2
max. 3
1 to 5
TFT/HB121PR8yyy-zzzz
316
-0/+2
258
-0/+2
TFT/HB150PR8yyy-zzzz
378
-0/+2
295
-0/+2
Tab. 13
TFT/HBxxxPU8yyy-zzzz Mounting dimensions
Fig. 7
Required Cut out HBxxxPU8yyy-zZZZ
Mounting Angle:
Mounting Angle must be 90°
Cooling Space:
To ensure cooling leave enough of free space around product to allow free air flow.