Protouch-wide: user documentation
DOC/PROTOUCH-8; V1.6
DOC_PROTOUCH_8-E_V1.6.docx
Seite 32 von 41
© 2019 Syslogic Datentechnik AG | All rights reserved
4
Technical Data
4.1
General Electrical Data (based on Compact8 IPC)
Important Note
Do not operate the PROTOUCH-WIDE outside of the recommended operating conditions. Otherwise lifetime and
performance will degrade. Operating the board and the display outside of the absolute maximum ratings may damage
the hardware.
Absolute Maximum Ratings
Parameter
Symbol
min
nom
max
Unit
isolation logic to chassis (AC, 60s, 500m a.s.l., Ta=25°C)
100
500
Vrms
Isolation Ethernet to logic (AC, 60s, 500m asl, Ta=25°C)
1500
Vrms
creepage distance logic to chassis and PCB boarder
0.5
mm
creepage distance Ethernet to logic
1.0
mm
creepage distance Ethernet to chassis and PCB boarder
1.0
mm
storage temperature range
Tst
-25
25
75
°C
Tab. 15
General Absolute Maximum Ratings
Recommended Operating Conditions
Parameter
Symbol
min
nom
max
internal logic supply voltage
Vcc
10
12/24
30
Vdc
Battery backup voltage
Vbatt
2.7
3.0
3.3
V
operating temperature range
Ta
-25
2
70
3
°C
Operating humidity (not condensing)
Rh
8
90
%
USB 2.0 Supply Current
Iusb2
500
mA
USB 3.0 Supply Current
Iusb3
1000
mA
Tab. 16
General Recommended Operating Conditions
To ensure proper operation of the device keep inside temperature below 70°C.
Operation at
70
−5
+0
°𝐶
inside temperature is only possible during 240 consecutive hours.
For this the temperature sensor on the SL8 board can be used; see board documentation for
details
Important Note
Maximum ambient temperature is highly dependent on mounting, air flow and CPU/GPU load; with the
Intel Thermal Monitoring
Technologies
the processor automatically reduces the internal CPU when the critical thermal trip points are reached to prevent
damage.
2
Cold start up: -20°C
3
depending on specific use case