Protouch-wide: user documentation
DOC/PROTOUCH-WIDE-R; V1.1
DOC_PROTOUCH_WIDE-R_V1.0.docx
Seite 20 von 41
© 2018 Syslogic Datentechnik AG | All rights reserved
2.7
Maintenance
To replace the battery or the C-Fast Data storage it is required to remove the service cover.
Shutdown the system and disconnect from power supply and all other connections
Make sure the device has cooled down to room temperature
Only open the device in an ESD protected area
Danger of explosion if battery is incorrectly replaced. Replace only with same or
equivalent type recommended by the manufacturer. Dispose of used batteries
according to the manufacturer’s instructions.
2.7.1
Removing Service Cover
TFT/HB101PR8xxx-yyy
1.
Disconnect device from power.
2.
Remove the two knurled screws highlighted and remove the cover.
3.
After removing the cover the C-Fast and the battery slot are accessible.