user documentation
DOC_PROTOUCH_WIDE-R_V1.0.docx
Page 37 of 41
© 2019 Syslogic Datentechnik AG | All rights reserved
4.4
Use cases
To give an idea on how to operate the device in good condition several us cases have been defined to help system integrators choose the best
way on how to install the PROTOUCH-WIDE-R
Mounting
position
CPU
load
GPU
load
Backlight
dimming
Display on-time
Airflow through
device
max. ambient
temperature
90°
30%
20%
100% (~850cd/m
2
)
all the time
1m/s
55°C
90°
30%
20%
50% (~425cd/m
2
)
all the time
1m/s
58°C
90°
30%
20%
100% (~850cd/m
2
)
all the time
2.5m/s
60°C
90°
30%
20%
50% (~425cd/m
2
)
all the time
2.5m/s
65°C
90°
30%
20%
20% (~170cd/m
2
)
5min on/10min off
none
60°C
To ensure proper operation of the device keep inside temperature below 70°C.
Operation at
70
−5
+0
°𝐶
inside temperature is only possible during 240 consecutive hours.
For this the temperature sensor on the RSL8 board can be used; see board documentation for
details
Important Note
Maximum ambient temperature is highly dependent on mounting, air flow and CPU/GPU load; with the
Intel Thermal Monitoring
Technologies
the processor automatically reduces the internal CPU when the critical thermal trip points are reached to prevent
damage.