Ordering Code
W - Width Dimension
200 mm to 800 mm
H - Height Dimension
375 mm to 1000 mm
A - Product type
00
No Grille, duct connectable on both sides**
01
Grille on one side /Zinc/ + connection for duct available on either side**
02
Grille on one side /RAL 9003/ + connection for duct available on either side
11
Grille on both sides /Zinc/**
22
Grille on both sides /RAL 9003/
B - Type of Activation
H0
(Manual crank, no switches)
H2
(Manual crank, 2 switches 230V AC or 24V AC/DC)
B230T
(230V AC Belimo Actuator)
B24T
(24V AC/DC Belimo Actuator)
BST0
(230V AC Supply comm. unit & 24V AC/DC Belimo Actuator)
B24T-SR
(24V AC/DC Belimo Actuator, modulated 0...10 V)
G230T
(230V AC Gruner Actuator)
G24T
(24V AC/DC Gruner Actuator)
GST0
(24V AC/DC Supply comm. unit & 24V AC/DC Gruner Actuator)
G24T-SR
(24V AC/DC Gruner Actuator, modulated 0...10 V)
BSD230T
(230V AC Supply unit & 24V AC/DC Smoke detector & 24V AC/DC Belimo Actuator), Available only with type 11 and 22.
GSD230T
(AC/DC 230 V Transformer & 24V AC/DC Smoke detector & 24V AC/DC Gruner Actuator), Available only with type 11 and 22.
BSD24T
(24V AC/DC Smoke detector & 24V AC/DC Belimo Actuator), Available only with type 11 and 22.
GSD24T
(24V AC/DC Smoke detector & 24V AC/DC Gruner Actuator), Available only with type 11 and 22.
Example of the F-B90 fire damper order code
F-B90-315×375-00-B230T
Multiblade fire damper with width of 315 mm and height of 375 mm, without a grille. Activated by a 230 V Belimo actuator.
Summary of Contents for F-B90
Page 1: ...F B90 Multiblade Fire damper ...
Page 14: ...14 69 F B90 Dimensions Free area ...
Page 15: ...15 69 F B90 Dimensions ...
Page 16: ...16 69 F B90 Weights ...
Page 17: ...17 69 F B90 ...
Page 18: ...18 69 F B90 ...
Page 23: ...23 69 F B90 Types 00 01 02 installed in the wall Max EI90S ...
Page 24: ...24 69 F B90 ...
Page 28: ...28 69 F B90 Types 11 22 installed in the wall Max EI90S EI120 ...
Page 29: ...29 69 F B90 ...
Page 32: ...32 69 F B90 Types 00 01 02 installed in the wall Max EI90S ...
Page 33: ...33 69 F B90 ...
Page 37: ...37 69 F B90 Types 11 22 installed in the wall Max EI90S EI120 ...
Page 38: ...38 69 F B90 ...
Page 41: ...41 69 F B90 Types 00 01 02 installed in the wall Max EI90S ...
Page 44: ...44 69 F B90 Types 11 22 installed in the wall Max EI90S EI120 ...
Page 47: ...47 69 F B90 ...
Page 48: ...48 69 F B90 ...
Page 49: ...49 69 F B90 ...
Page 61: ...61 69 F B90 Operation manual ...
Page 62: ...62 69 F B90 ...
Page 63: ...63 69 F B90 ...
Page 64: ...64 69 F B90 ...
Page 66: ...66 69 F B90 ...
Page 69: ...Systemair DESIGN 2020 10 07 HandBook_F_B90_en GB 1D2E1FF0 E010 11EA E8DD 8BBB7258CB9B ...