background image

1

General notes

1.1

Structure of the operating instructions

Before installation and start-up, read this manual carefully to ensure correct use!
We emphasize that these operating instructions apply to speci

c units only, and are in no way 

valid for the complete system!

Use these operating instructions to work safely with and on the device. They contain safety instruc-
tions that must be complied with as well as information that is required for failure-free operation of the 
device.
Keep these operating instructions together with the device. It must be ensured that all persons that 
are to work on the device can refer to the operating instructions at any time.
Keep the operating instructions for continued use. They must be passed-on to all successive owners, 
users and 

nal customers.

1.2

Target group

The operating instructions address persons entrusted with planning, installation, commissioning and 
maintenance and servicing and who have the corresponding quali

cations and skills for their job.

1.3

Exclusion of liability

Concurrence between the contents of these operating instructions and the described hardware and 
software in the device has been examined. It is still possible that non-compliances exist; no guarantee 
is assumed for complete conformity. To allow for future developments, construction methods and 
technical data given are subject to alteration. We do not accept any liability for possible errors or 
omissions in the information contained in data, illustrations or drawings provided. 
We accept no liability for damage caused by misuse, incorrect use, improper use or as a consequence 
of unauthorized repairs or modi

cations.

1.4

Copyright

These operating instructions contain copyright protected information. The operating instructions may 
be neither completely nor partially photocopied, reproduced, translated or put on data medium without 
previous explicit consent. Infringements are liable for damages. All rights reserved, including those 
that arise through patent issue or registration on a utility model. 

2

Safety instructions

This chapter contains instructions to prevent personal injury and property damage. These instructions 
do not lay claim to completeness. In case of questions and problems, please consult our company 
technicians. 

2.1

Intended use

The equipment is to be used solely for the purposes speci

ed and con

rmed in the order. Other uses 

which do not coincide with, or which exceed those speci

ed will be deemed unauthorised unless 

contractually agreed. Damages resulting from such unauthorised uses will not be the liability of the 
manufacturer. The user will assume sole liability.
Reading these operating instructions and complying with all contained instructions - especially the 
safety noti

cations contained therein - are considered part of intended use. To consider is also the 

manual of attached components. Not the manufacturer, rather the operator of the device is liable for 
any personal harm or material damage arising from non-intended use!

2.2

Explanations of symbols 

Safety instructions are highlighted with warning triangles and are depicted according to the degree of 
hazard as follows.

Attention!

General hazardous area. Death or severe injury or signi

cant property damage can occur if the 

corresponding precautions are not taken!

Operating Instructions 

FRQ5S-E-6/10A

General notes

L-BAL-E247-GB 1512 Index 001

Part.-No. 00163444-42

4/17

Summary of Contents for FRQ5S-E-10A

Page 1: ...with sine lter for 1 fans Operating Instructions Speed controller with 5 step switch for presetting the fan speed Keep for reference Software version D1628A from Version 11 03 L BAL E247 GB 1512 Index...

Page 2: ...tdoor installation 8 4 4 Installation location for agriculture 9 4 5 Temperature in uences during commissioning 9 5 Electrical installation 9 5 1 Safety precautions 9 5 2 EMC compatible installation 9...

Page 3: ...ical data 14 8 1 1 Max load dependent on ambient temperature and line voltage 15 8 2 Connection diagram 16 8 3 Dimensions mm 16 8 4 Manufacturer reference 17 Operating Instructions FRQ5S E 6 10A L BAL...

Page 4: ...consequence of unauthorized repairs or modi cations 1 4 Copyright These operating instructions contain copyright protected information The operating instructions may be neither completely nor partiall...

Page 5: ...directives rules for the prevention of accidents and the corresponding national as well as regional and in house regulations Personnel to be trained or instructed and apprentices are only permitted to...

Page 6: ...ufacturer s original spare parts wearing parts accessories These parts are specially designed for this device If parts from other sources are used there is no guarantee that they are designed and prod...

Page 7: ...tep 5 to step 0 is not possible 0 1 2 3 4 5 0 Hz 10 Hz 20 Hz 30 Hz 40 Hz 50 Hz 23 05 2013 v_5_step_icontr_basic_sa vsd The output frequency can be adapted by an internal potentiometer if necessary inv...

Page 8: ...an be easily accessed Depending on the housing model cut off necessary cable inlets respectively to the cable diameter Or alternative use cable inlet for cable glands Metal sheet housings are supplied...

Page 9: ...the device Disregarding this regulation can lead to severe personal injury For metal cable inlets the necessary protective earth connection to the bottom of the housing is made by screws The device ma...

Page 10: ...between two outer conductors all current sensitive fault current circuit breakers must be used EN 50 178 Art 5 2 5 5 Inverter output 5 5 1 Motor connection The motor leads are connected to the termin...

Page 11: ...at certain frequencies Potemtiometer adjustable with a screwdriver Left stop No reduction i e output frequency e g in step 5 50 Hz factory setting diagram Right stop Maximum reduction 25 i e output fr...

Page 12: ...tion below 3 Hz switch off by the enable switch off of line voltage or in case of a fault the relay de energizes 5 9 Bypass circuit Please observe the following during bypass switching controller shun...

Page 13: ...tion above 5 Hz terminals 21 24 bridged De energized at modula tion below 3 Hz 21 22 bridged Temperature management active The device has an active temperature management to protect it from damage due...

Page 14: ...at the output 2 At rated voltage cos 0 8 at the output values for different speci cations on request 3 Max supply side line fuse according to DIN EN 60204 1 classi cation VDE0113 chapter 1 Line voltag...

Page 15: ...pendent on ambient temperature and line voltage The maximum permissible temperature for the rated current at rated voltage is speci ed as rated temperature Since the dissipation of the power loss heat...

Page 16: ...ernal thermostats 2 TB 1 Kontaktbelastung Contact rating max AC 250 V 2 A 5 3 UMPO09K13 17 03 2015 FRQ5S E 6 10A 22 24 21 BU RD BK 0 1 2 3 5 4 1 Line 1 208 277 V 50 60 Hz 2 1 Motor with internal therm...

Page 17: ...ve any questions concerning the use of our products or plan special uses please contact Systemair Industriev gen 3 73930 Skinnskatteberg Telefon 46 0 222 440 00 Telefax 46 0 222 440 99 mailbox systema...

Reviews: