Dimensions of the units
D
Employees in charge of operation/control/maintenance
The units are constructed and built with a fully integrated control system. After start-up and hand-over from installer to operators, the
unit operates fully automatically.
Indications of operating status as well as indication of faults are visible on the display. The operators can enter new parameters in the
controller. The controller can be connected to a BMS system so that new parameters can be selected. The operators do not need to
open inspection doors for the operation.
Skilled technicians must carry out maintenance, as well as, repairs.
E
Intended use and range of applications
The air handling units are intended for the transport and treatment of air between -40°F and +110°F The units are exclusively for
comfort ventilation. The units are not intended for corrosive environments unless specified otherwise.
F
Unintended use and misuse – inappropriate applications for the machine
Please note that air-handling units that are intended for outdoor installations need to be indicated as such at the time of design. Air-
handling units are intended for the sole purposes of transporting and conditioning the outside or return air, and providing ventilation to
an indoor environment.
Geniox air handling units are not designed to be used in highly corrosive environments, applications with solid particles in the air stream,
chlorine, saltwater, or any toxic chemicals/gas in and around the air-handler environment. Care also must be taken when using the units
with high humidity applications.
Systemair does not assume any responsibility to the safety of the installation/operation, the resulting quality of the process/production,
the health of occupants, and/or unit performance if the environment is not suitable to the AHU design. Any misuse of the mechanical
structure/components of the air-handler or changes to the final unit build may result in unsafe conditions. Any failure to adhere to the
aforementioned will invalidate the factory warranty.
Furthermore, Geniox units are not intended as:
-
Transportation pods
-
Storage vessels or any type of storage
-
Partially finished duct systems
-
Incomplete construction areas or project
-
Do not use with unfinished or improper ancillary trades (controls, plumbing, electrical, etc.)
W
o
W
i
H
i
H
D
H
S
Unit Size
W
o
H
S
H
D
W
i
H
i
Geniox 10
66
35
66
61
30
Geniox 12
74
39
74
69
33
Geniox 15
82
43
82
77
37
Geniox 20
90
47
90
85
41
Geniox 25
98
50
98
93
45
Geniox 30
110
54
106
104
49
Geniox 35
117
58
113
112
53
Geniox 40
125
62
121
120
57
* The length of the unit depends on the functions and components selected
by user and it is shown on the technical reports and unit nameplate.
* For more accurate dimensions and drawings select the desired unit using
SystemairClick online software.
* All the dimensions are in inches.
10
| Employees in charge of operation/control/maintenance
Summary of Contents for Geniox 10
Page 2: ...Geniox Air Handling Unit User Manual 3060386...
Page 6: ...Geniox Air Handling Unit User Manual 3060386...
Page 35: ...3060386 Geniox Air Handling Unit User Manual Star up adjustments use and commissioning 29...
Page 61: ...3060386 Geniox Air Handling Unit User Manual ERW maintenance 4 8...
Page 62: ...Geniox Air Handling Unit User Manual 3060386 5 1 Roof curb master tables...
Page 63: ...3060386 Geniox Air Handling Unit User Manual Roof curb master tables 5 2...
Page 64: ...Geniox Air Handling Unit User Manual 3060386 5 3 Roof curb master tables...
Page 65: ...3060386 Geniox Air Handling Unit User Manual Roof curb master tables 5 4...
Page 66: ...Systemair NA 8 Rouse Street Tillsonburg ON N4G 5W8 Toll free 800 688 6363...