Installation |

7

5.1

Location and Space Requirements

The SAVE VTR 250/B should preferably be installed in a separate room (e.g. storeroom, laundry room or similar.).

When choosing the location it should be kept in mind that the unit requires maintenance regularly and that the inspec-
tion door should be easily accessible. Leave free space for opening the door and for taking out the main components
(figure 3.1).

5.2

Wall preparation for mounting bracket

The unit should be installed in such a way that there is no vibration noise
coming from the wall on which the unit is installed.

5.3

Outdoor Air Intake Location Recommendation

Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic, etc. Exhaust air should ideally be led via a roof cowl to the out-
side and with a good distance from the outdoor air intake, windows, etc.

5.4

Access to Power supply

The SAVE VTR 250/B is supplied with approximately 1,5 m cable and plug for 230V, single phase earthed connection.

Make sure a power outlet is reachable by the plug.

6

Installation

Important

• The device may only be installed by qualified, instructed and trained personnel. The persons must know

the relevant safety directives in order to recognise and to avoid risks.

254496 | v01

Summary of Contents for SAVE VTR 250/B

Page 1: ...Document in original language 254496 v01 SAVE VTR 250 B Installation instructions GB...

Page 2: ...s the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed specifications Systemair is not liable or bound by...

Page 3: ...6 4 1 Transport and storage 6 4 2 Delivery Unloading 6 5 Prerequisites for Installation 6 5 1 Location and Space Requirements 7 5 2 Wall preparation for mounting bracket 7 5 3 Outdoor Air Intake Loca...

Page 4: ......

Page 5: ...laim 1 3 Type label Before calling your service representative make a note of the specification and production number from the type label which can be found next to the external connections and inside...

Page 6: ...by an authorized installer and in accordance with local rules and regulations Warning This product is not intended to be used by children or people with reduced physical or mental ability or lack of e...

Page 7: ...Technical Data 3 3 1 Dimensions and Weight Fig 2 Dimensions of left hand unit 254496 v01...

Page 8: ...4 Technical Data Fig 3 Dimensions of right hand unit Water coil connections Drainage The unit weight is 56 kg 254496 v01...

Page 9: ...unit is in tended to be stopped by the user manually or due to calendar function we recommend to install air tight dampers at ex tract and supply air ducts The dampers will ensure that no air circulat...

Page 10: ...d be stored and transported in such a way that it is protected against physical damage It should be covered so dust rain and snow cannot enter and damage the unit and its components Important Use the...

Page 11: ...mended installation location for the outdoor air intake is the northern or eastern side of the building and with a distance to openings for discharge of stale ventilation air kitchen ventilator centra...

Page 12: ...8 Installation C concrete bricks W wood block G gypsum M mineral wool X adaptable height according to needs Make sure the mounting bracket is completely level 254496 v01...

Page 13: ...in moisture damage Do not install the ducts directly against structural building elements to avoid sound propagation Use acoustic insulation and sound attenuators Note The type of ventilation ducts a...

Page 14: ...t temperature sensor units with heater 11 Analog input 5 Freely configurable 12 Digital input 1 Rotor guard sensor only for VSR VTR models 13 Digital input 2 Freely configurable Cooker hood VTR 150 K...

Page 15: ...10 V or a digital input 24 V UI1 default configuration Pressure guard UI2 default configuration Cooker hood UI3 default configuration Fire alarm UI4 default configuration Refresh 24V Maximum current...

Page 16: ...ke modifications Choose heating type or none Reset filter changer timer if necessary Finish startup wizard with OK button All additional changes post startup wizard must be recorded in the Commissioni...

Page 17: ...uct is compliant with the European WEEE Directive and related national waste legislation When disposing the unit follow your local rules and regulations This product packing materials are recyclable a...

Page 18: ...l appliances Part 2 40 Particular requirements for electrical heat pumps air conditioners and dehumidifiers EN 50106 Safety of household and similar appliances Particular rules for routine tests refer...

Page 19: ...254496 v01...

Page 20: ...SAVE VTR 250 B Installation instructions 254496 en_GB 2021 03 22 v01 Systemair UAB Lin st 101 LT 20174 Ukmerg LITHUANIA Phone 370 340 60165 Fax 370 340 60166 www systemair com...

Reviews: